Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2017-11-16 to 2017-12-05
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Batch No. of test material: AD16081001
- Expiration date of the batch: 2019-08-09

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature
- Stability under test conditions: Stable under ambient conditions
Key result
Temp.:
20 °C
Vapour pressure:
0 Pa
Temp.:
25 °C
Vapour pressure:
0 Pa

The vapour pressure was measured in the temperature range of 90 to 130 °C. For the evaluation the vapour pressure values in the range of 90 to 120 °C were used.

Stage No.

Temperature, °C

Δm/Δt, mg/min

Vapour pressure, Pa

1

90

8.7285 x 10-5

2.3609 x 10-2

2

95

1.5908 x 10-4

4.3324 x 10-2

3

100

3.0665 x 10-4

8.4076 x 10-2

4

105

6.3614 x 10-4

1.7558 x 10-1

5

110

1.3644 x 10-3

3.7908 x 10-1

6

115

3.8532 x 10-3

1.0775

7

120

5.9338 x 10-3

1.6700

Conclusions:
The vapour pressure of the test item was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20 and 25 °C:
Vapour pressure at 20 °C: 1.895E-8 Pa
Vapour pressure at 25 °C: 6.337E-8 Pa
Executive summary:

A study was conducted according to OECD TG 104, Regulation (EC) No 440/2008 method A.4 and OPPTS 830.7950 to determine the vapour pressure of the test item. The vapour pressure of the test item was determined at temperatures between 90 and 130 °C using the effusion method (Knudsen cell). For the evaluation the vapour pressure values in the range of 90 to 120 °C were used. The vapour pressure of the test item was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20 and 25 °C. The vapour pressure was calculated to be 1.895E-8 Pa at 20 °C and 6.337E-8 Pa at 25 °C, respectively.

Description of key information

The vapour pressure of the test item was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20 and 25 °C:

Vapour pressure at 20 °C: 1.895E-8 Pa

Vapour pressure at 25 °C: 6.337E-8 Pa

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information

A study was conducted according to OECD TG 104, Regulation (EC) No 440/2008 method A.4 and OPPTS 830.7950 to determine the vapour pressure of the test item. The vapour pressure of the test item was determined at temperatures between 90 and 130 °C using the effusion method (Knudsen cell). For the evaluation the vapour pressure values in the range of 90 to 120 °C were used. The vapour pressure of the test item was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20 and 25 °C. The vapour pressure was calculated to be 1.895E-8 Pa at 20 °C and 6.337E-8 Pa at 25 °C, respectively.