Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 813-050-0 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Biodegradation in water: screening tests
Administrative data
Link to relevant study record(s)
- Endpoint:
- biodegradation in water: ready biodegradability
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2017-08-03 - 2017-08-31 (experimental phase)
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.4-D (Determination of the "Ready" Biodegradability - Manometric Respirometry Test)
- Version / remarks:
- Commission Regulation 440/2008/EC, Method C.4-D of May 30, 2008: Manometric Respirometry Test (EEC Publication No. L 142/496, May 2008)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
- Version / remarks:
- OECD Guideline for Testing of Chemicals No. 301 F: "Ready Biodegradability: Manometric Respirometry Test", adopted July 17, 1992
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At 20 ± 5 °C, in the dark - Oxygen conditions:
- aerobic
- Inoculum or test system:
- activated sludge, domestic (adaptation not specified)
- Details on inoculum:
- - Source of inoculum/activated sludge (e.g. location, sampling depth, contamination history, procedure): Aerobic activated sludge, microorganisms from a domestic waste water treatment plant was supplied by the sewage treatment plant Bensheim, Germany
- Preparation of inoculum for exposure: The aerobic activated sludge used for this study was deposited for 45 minutes and afterwards washed by centrifugation and the supernatant liquid phase was decanted. The solid material was re-suspended in test water and centrifuged again. This procedure was done three times. An aliquot of the final sludge suspension was weighed, dried and the ratio of wet sludge to its dry weight was determined. Based on this ratio, calculated aliquots of washed sludge suspension, corresponding to 3.5 g dry material per litre were mixed with test water and aerated overnight. This suspension was used for the experiment. - Duration of test (contact time):
- 28 d
- Initial conc.:
- >= 51.23 - <= 52.46 mg/L
- Based on:
- test mat.
- Remarks:
- Concentration given as 12.8 and 12.5 mg per flask, containing 244 ml
- Parameter followed for biodegradation estimation:
- O2 consumption
- Details on study design:
- TEST CONDITIONS
- Composition of medium:
Reconstituted Test Water: Analytical grade salts were added to pure water to prepare the following stock solutions:
a) 8.5 g KH2PO4, 21.75 g K2HPO4, 33.4 g Na2HPO4 x 2 H2O, 0.5 g NH4Cl filled up with pure water to 1000 mL volume; The pH-value was 7.4.
b) 11.25 g MgSO4 x 7 H2O filled up with pure water to 500 mL volume
c) 18.2 g CaCl2 x 2 H2O filled up with pure water to 500 mL volume
d) 0.125 g FeCl3 x 6 H2O filled up with pure water to 500 mL volume
In order to avoid precipitation of iron hydroxide in the stock solution d), one drop of concentrated HCl per litre was added before storage.
50 mL of stock solution a) and 5 mL of the stock solutions b) to d) were combined and filled up to a final volume of 5000 mL with pure water.
- Solubilising agent (type and concentration if used): Silicone oil AR20 was used as an emulsifying agent.
- Test temperature: 22°C ± 1°C
- pH:
7.5 to 7.6 (measured at the start of the test)
7.5 to 8.1 (measured at the end of the test)
- pH adjusted: no
- Aeration of dilution water: overnight, after addition of the sludge
- Suspended solids concentration: 2 ml of washed sludge suspension, corresponding to 3.5 g dry material per litre were mixed with test water to a final volume of 244 ml
- Continuous darkness: yes
TEST SYSTEM
- Culturing apparatus:
Type and Size: Manometric Test System with test flasks containing a volume of approximately 500 mL.
Apparatus: BSB/BOD-Sensor-System, Aqualytic Dortmund, Germany
Principle: The test flasks were incubated at 22°C ± 1°C. The pressure decrease in the reaction vessels was measured over complete experimental phase of 28 days using the BSB/BOD-Sensor-System, Aqualytic Dortmund, Germany. The test flasks were closed gas-tight by a measuring head.
- Number of culture flasks/concentration: 2
- Test performed in closed vessels due to significant volatility of test substance: no
- Test performed in open system: no
- Details of trap for CO2 and volatile organics if used: Potassium hydroxide solution (45%) was used for trapping the produced carbon dioxide. The amount of O2 consumed by the activated sludge was calculated from the decrease of pressure in the reaction vessel.
SAMPLING
The change of pressure in the test flasks was measured by means of a manometric method (BSB/BOD-Sensor-System, Aqualytic Dortmund, Germany) each day.
The temperature was recorded by means of the automated software AMR Wincontrol©.
pH-values were measured in procedure control, a separately prepared test flask with test item (to prevent loss of test item in the test flasks) and a separately prepared test flask without test item (control) at test start and in all flasks at the end of the test, except in the abiotic and toxicity control, using a pH-electrode WTW pH 340i.
CONTROL AND BLANK SYSTEM
- Inoculum blank: 1 flask
- Abiotic sterile control: 1 flask
- Toxicity control: 1 flask - Reference substance:
- benzoic acid, sodium salt
- Remarks:
- ThODNH4: 1.666 mg oxygen per mg sodium benzoate (calculated)
- Key result
- Parameter:
- % degradation (O2 consumption)
- Value:
- < 10
- Sampling time:
- 28 d
- Remarks on result:
- other: not readily biodegradable
- Details on results:
- The criterion for ready biodegradability under the conditions of a manometric respirometry test is the degradation of the test item of at least 60%, reached within a 10-day window; the 10-day window starts when the degradation of the test item reaches at least 10% degradation.
DETDI did not reach 10% degradation during the incubation time of 28 days and therefore the 10 day window criterion was not passed. The mean biodegradation at test end after 28 days was 0% (ThODNH4, ThODNO3). - Validity criteria fulfilled:
- yes
- Interpretation of results:
- not readily biodegradable
- Conclusions:
- The biodegradation of the test item was performed under GLP according to OECD 301F. Hence, the results can be considered to be sufficiently reliable to assess the ready biodegradability of the test item. The degradation rate of DETDI did not reach 60% within the 10-day window or after 28 days.
Therefore, DETDI is considered to be not readily biodegradable. - Executive summary:
This study was designed to comply with the following methods:
- Commission Regulation 440/2008/EC, Method C.4-D of: Manometric Respirometry Test (EEC Publication No. L 142/496, May 2008)
OECD Guideline for Testing of Chemicals No. 301 F: "Ready Biodegradability: Manometric Respirometry Test", adopted
Aerobic activated sludge (microorganisms from a domestic wastewater treatment plant) was supplied by the sewage treatment plant of Bensheim.
The test item DETDI was investigated for its ready biodegradability in a manometric respirometry test over a period of 28 days. The biodegradation was followed by the oxygen uptake of the microorganisms during exposure. As a reference item sodium benzoate was tested simultaneously under the same conditions as the test item, and functioned as a procedure control.
Degradation rate of test item calculated by the oxygen consumption of the aerobic activated sludge microorganisms after 28 days of incubation at 22°C ± 1°C, darkness.
Test Item Loading Rate (initial concentration in medium C0) was 51.8 mg/L corresponding to an oxygen demand of about 100.9 mg/L (ThODNH4) and 129.7 mg/L (ThODNO3).
54.5 mg/L corresponding to an oxygen demand of about 90.8 mg/L (ThODNH4) of sodium benzoate served as positive control.
The criterion for ready biodegradability under the conditions of a manometric respirometry test is the degradation of the test item of at least 60%, reached within a 10-day window; the 10-day window starts when the degradation of the test item reaches at least 10% degradation.
DETDI did not reach 10% degradation during the incubation time of 28 days and therefore the 10 day window criterion was not passed. The mean biodegradation at test end after 28 days was 0% (ThODNH4, ThODNO3).
Therefore, DETDI is considered to be not readily biodegradable based on ThODNH4.and ThODNO3.
The reference item sodium benzoate was sufficiently degraded to 85% after 14 days and to 94% after 28 days of incubation, thus confirming the suitability of the aerobic activated sludge inoculum used.
In the toxicity control containing both, the test item and the reference item sodium benzoate, 34% biodegradation was noted within 14 days and 36% biodegradation after 28 days of incubation (based on ThODNH4). According to the test guidelines, the test item can be assumed to be not inhibitory to the aerobic activated sludge microorganisms because degradation was >25% within 14 days.
Reference
Description of key information
The ready biodegradation potential of DETDI was determined in a Manometric Respirometry Test according to OECD Technical Guideline 301F. The degradation rate of DETDI never reached 10%.
Therefore, DETDI: 3,5-Diethyltoluene-2,4-diisocyanate is considered not to be readily biodegradable.
Key value for chemical safety assessment
- Biodegradation in water:
- not biodegradable
- Type of water:
- freshwater
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.