Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 225-443-9 | CAS number: 4851-50-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
In the available studies for skin irritation/corrosion and eye irritation solvent Green 28 was not irritating/corrosive.
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin irritation: in vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- study well documented, meets generally accepted scientific principles, acceptable for assessment
- Principles of method if other than guideline:
- Two rabbits were applied 500 µl of the test substance (Macrolexgrün G) at the inner side of one of the ears. The test material was fixed by an adhesive bandage for 24 hours. After 1 and 24 hours and 2, 3, 5, 6 and 7 days the skin areas were scored for erythema and edema according to Draize.
- GLP compliance:
- no
- Species:
- rabbit
- Strain:
- not specified
- Type of coverage:
- not specified
- Preparation of test site:
- not specified
- Vehicle:
- not specified
- Controls:
- not required
- Amount / concentration applied:
- 500 mg
- Duration of treatment / exposure:
- 24 days
- Observation period:
- 7 days
- Number of animals:
- 2 animals
- Irritation parameter:
- erythema score
- Basis:
- mean
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: score = 0 at any time point
- Irritation parameter:
- edema score
- Basis:
- mean
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: score = 0 at any time point
- Irritant / corrosive response data:
- Erythema and edema scores were = 0 at any time point.
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- Erythema and edema scores were = 0 at any time point.
- Executive summary:
Two rabbits were applied 500 µl of the test substance (Macrolexgrün G) at the inner side of one of the ears. The test material was fixed by an adhesive bandage for 24 hours. After 1 and 24 hours and 2, 3, 5, 6 and 7 days the skin areas were scored for erythema and edema according to Draize. Erythema and edema scores were 0 at any time point. Macrolexgrün G was not irritating in this test.
Reference
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- study well documented, meets generally accepted scientific principles, acceptable for assessment
- Principles of method if other than guideline:
- Macrolexgrün G was applied to the eyes of 2 rabbits. Post observation time was 7 days.
- GLP compliance:
- no
- Species:
- rabbit
- Strain:
- not specified
- Vehicle:
- not specified
- Controls:
- not required
- Amount / concentration applied:
- ca. 50 mg
- Duration of treatment / exposure:
- 7 days (eyes were not washed).
- Observation period (in vivo):
- 7 days
- Number of animals or in vitro replicates:
- 2 animals
- Irritation parameter:
- cornea opacity score
- Basis:
- mean
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: score = 0 at any time point
- Irritation parameter:
- iris score
- Basis:
- mean
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 2
- Reversibility:
- other: score = 0 at any time point
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Time point:
- 24/48/72 h
- Score:
- 0.2
- Max. score:
- 3
- Reversibility:
- fully reversible within: 48 hours
- Irritation parameter:
- chemosis score
- Basis:
- mean
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: score = 0 at any time point
- Irritant / corrosive response data:
- Cornea opacity, iris and chemosis score were 0 (24,48, 72 hours). The conjunctivae score was 0.2 (24, 48, 72 hours). It was fully reversible within 48 hours.
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- Not irritating. Cornea opacity, iris and chemosis score were 0 (24,48, 72 hours). The conjunctivae score was 0.2 (24, 48, 72 hours). It was fully reversible within 48 hours.
- Executive summary:
Macrolexgrün G was applied to the eyes of 2 rabbits. Post observation time was 7 days. Cornea opacity, iris and chemosis score were 0 (24,48, 72 hours). The conjunctivae score was 0.2 (24, 48, 72 hours). It was fully reversible within 48 hours. Macrolexgrün G was not irritating in this test.
Reference
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Justification for classification or non-classification
Solvent Green 28 is not irritating/corrosive to the skin and not irritating to the eyes. According to CLP classification criteria (Regulation (EC) No 1272/2008) a classification is not justified.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.