Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: OECD guideline, GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report date:
2003

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
2003-03-27
Type of method:
pycnometer method

Test material

Constituent 1
Reference substance name:
SEPIWHITE MSH
IUPAC Name:
SEPIWHITE MSH
Details on test material:
- Identification: SEPIWHITE MSH
- Identification of the flask: SEPIWHITE SMH Batch n°: 0214400005
Validity date: 24/05/2005
- Batch: 02 144 00005
- Expiry date: May 24, 2005
- Supplier: SEPPIC
- Appearance: whitish powder
- Packaging: 2 plastic bags
- Quantity received: 2 x 1 L
- Date of the reception: October 10, 2003
- Storage: in darkness at room temperature
- Identification number for the study: 03-089

Results and discussion

Density
Type:
relative density
Density:
ca. 1.081 other:
Temp.:
19.4 °C
Remarks on result:
other: +/-0.014

Applicant's summary and conclusion

Conclusions:
The relative density mean value of the test item by the stereopycnometer method
measurement was:
D (at 19.4°C ) = 1.081 ± 0.014 (mean of 3 assays).
Executive summary:

RELATIVE DENSITY STEREOPYCNOMETER METHOD

In compliance with Commission Directive 92/69/EEC - A3 method (1992) OECD Guideline No. 109 (1995)

AMENDMENTS

No amendment to the study plan was requested. DEVIATIONS No incident, which could have affected the quality or the interpretation of the results obtained, was observed.

RESULTS

The relative density mean value of the test item using the gas comparison method with the stereopycnometer was: D (at 19.4°C) = 1.081 ± 0.014 (mean value of three assays)