Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 1998
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
1995
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
1992
GLP compliance:
no
Type of method:
other: Calculation using the Modified Watson Correlation
Key result
Temp.:
25 °C
Vapour pressure:
0.002 Pa
Remarks on result:
other: calculated result
Conclusions:
The vapour pressure of the test item was estimated to be 1.83E-3 Pa at 25 °C based on the boiling point calculated and using the Modified Watson Correlation.
Executive summary:

The vapour pressure of the test item was estimated to be 1.83E-3 Pa at 25 °C based on the boiling point calculated and using the Modified Watson Correlation according to OECD 104 and EU Method A.4.

Description of key information

The vapour pressure of the test item was estimated to be 1.83E-3 Pa at 25 °C based on the boiling point calculated and using the Modified Watson Correlation.

Key value for chemical safety assessment

Vapour pressure:
0.002 Pa
at the temperature of:
25 °C

Additional information