Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16-18 October 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The study was conducted according to an internationally recognised method, and under GLP. The substance is considered to be adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Version / remarks:
1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected on October 13 and 14, 2014 / signed on April 08, 2015
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
ca. 139.5 °C
Atm. press.:
ca. 101 325 Pa

Findings

Determination of the Flash Point

The results of the determinations are presented in the following tables.

Table 4.11/2.-Findings

Program

Expected flash point (setting)

in °C

Flash point (found)
in °C

Notes

Search

295

140.5

not used for calculation(pre-test)

EN ISO 2719-B

141

139.5

Value OK

EN ISO 2719-B

141

-

Measurement terminated, because the flash point visual visible, but the detector did not react.

Therefore the detector was cleaned and proved with Dodecan, the reference standard. Then the measurement was repeated.

EN ISO 2719-B

141

139.5

Value OK

Evaluation and Result

The flash point is given as the mean value of the duplicate determination. The measured flash point is therefore 139.5°C (corresponding to 412.7 K) at 101325 Pa.

Discussion

No difference between the two values was measured therefore the validity criteria of ≤ 2°C is met. For this reason, the determination was considered valid.

Interpretation of results:
GHS criteria not met
Conclusions:
The measured flash point is therefore 139.5 °C (corresponding to 412.7 K) at 101325 Pa.
Executive summary:

The flash point of the test substance was determined under GLP according to EU Method A.9 (Flash-Point), using a non-equilibrium closed cup and electrical ignition method (ISO2719 -Part B).

No difference between the two values was measured therefore the validity criteria of ≤ 2°C is met. For this reason, the determination was considered valid.

The measured flash point is stated as 139.5°C (corresponding to 412.7 K) at 101325 Pa (mean value of two independent determinations).

Description of key information

The substance is NOT classified according to Regulation (EC) N°1272/2008 (CLP criteria) and UN Globally Harmonized System (GHS criteria).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
139.5 °C

Additional information

The flash point of the test substance was determined under GLP according to EU Method A.9 (Flash-Point), using a non-equilibrium closed cup method (ISO2719 -PartB).

It is considered as a key study. The result is retained as key data for purpose of CSA.

This study is relevant for the classification regarding flammable properties.