Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Dibutyl 1,4,5,6,7,7-hexachlorobicyclo[2.2.1]hept-5-ene-2,3-dicarboxylate
EC Number:
217-192-9
EC Name:
Dibutyl 1,4,5,6,7,7-hexachlorobicyclo[2.2.1]hept-5-ene-2,3-dicarboxylate
Cas Number:
1770-80-5
Molecular formula:
C17H20Cl6O4
IUPAC Name:
dibutyl 1,4,5,6,7,7-hexachlorobicyclo[2.2.1]hept-5-ene-2,3-dicarboxylate

Test animals / tissue source

Species:
cattle
Strain:
not specified

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
neat, 750 µL
Duration of treatment / exposure:
10 min
Duration of post- treatment incubation (in vitro):
2h (illuminance measurement) and further 90 min (optical density measurement)
Number of animals or in vitro replicates:
3 corneas per test item

Results and discussion

In vitro

Results
Irritation parameter:
in vitro irritation score
Run / experiment:
mean
Value:
2.03
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Remarks:
none of the 3 corneas showed any opacity

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
When applied on bovine corneas, the test item had no eye irritancy potential. The mean irritation score was 2.03.