First-aid measures

Inhalation: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Immediately call a POISON CENTER or doctor/physician.

Skin contact: Wash with plenty of soap and water. IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. Immediately call a POISON CENTER or doctor/physician.

Eye contact: Wash the eyes with clean water for at least several minutes (desirably 15 minutes or longer), (Remove the contact lenses if possible.) and get medical attention by an eye specialist immediately. During washing, fully open the eyelid with fingers and wash in such a way as to let water reach to every corner of the eyeball and eyelid.

Ingestion: Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Fire-fighting measures

Extinguishing media: Chemical powder extinguisher, aqueous liquid foam (alcohol  resistance foam) fire extinguishing media, carbon dioxide, sand atomized water.

Unsuitable extinguishing media: No data available.

Specific hazards: At the time of fire poisonous gases can be generated.

Specific extinguishing methods:  Keep upwind of fire. Wear full fire-fighting turn-out gear (full Bunker gear) and respiratory protection (SCRA). Cool container with water spray. Fight fire with normal precautions from a reasonable distance.

Precautions for fire-fighters: During fire-fighting work, wear proper protective equipment.

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Promptly remove possible ignition sources from the vicinity. Use personal protection recommended in section 'Exposure controls and personal protection'. Isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental precautions: Do not flush to sewer or allow to enter waterways. Prevent scattering and spread by covering with antistatic sheet and the like.

Methods and materials for containment and cleaning up: Carefully shovel or sweep up spilled material and place in suitable container. Avoid generating dust. Eliminate all ignition sources. Use explosion-proof equipment. Dust can be a fire or explosion hazard. Vacuum or sweep material and place in a disposal container.

Handling and storage

Handling

Technical measures: During handling be sure to wear proper protective equipment (refer to section 'Exposure controls and personal protection'). Do not breath dust. The dust can be charged with static electricity. Suppress generation and accumulation of dust as much as possible. Take countermeasures for static electricity removal (grounding, others). Wear antistatic clothes and antistatic shoes to prevent human body electrification. Keep away from heat/sparks/open flames/hot surfaces – No smoking. Do not handle the containers harshly in such a way as to make them tumbled, dropped, given a shock or dragged.

Local/total ventilation: Use the ventilation equipment described in section 'Exposure controls and personal protection'.

Precautions: This product is hygroscopic

Precautions for safe handling: Absorption of moisture can generate hazardous gas like hydrogen fluoride. For this reason treatment under dried atmosphere is necessary. Re-drying is prohibited

Storage

Storage conditions: Keep away from sources of ignition – No smoking. Protect from sunlight. Store in a well ventilated place. Store in temperatures not exceeding 25°C/77°F.

Packaging material: Store in tightly closed container.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering controls: Install eye and body washing facilities near the handling place. Use closed equipment/machinery or use local ventilation equipment.

Personal protective equipment

Respiratory protection: Dust mask. Use NIOSH certified particulate respirator with APF=10

Hand protection: Protective gloves (Antistatic ones as desirable). Rubber or polyethylene gloves.

Eye protection: Protective glasses, goggle, protective face shield.

Skin and body protection: Protective clothes, protective shoes (Antistatic ones are desirable).

Stability and reactivity

Stability: Absorption of moisture can generate hazardous gas like hydrogen fluoride. For this reason treatment under dried atmosphere is necessary. Re-drying is prohibited.

Hazardous reactions: Stable under normal handling conditions.

Conditions to avoid: High temperature, high humidity, direct sunlight.

Incompatible materials: Acids, reducing agents, oxidising agents, bases, strong acids.

Hazardous decomposition products: Combustion gas can contain hazardous NOx, SOx and hydrogen fluoride gas.

Disposal considerations

Disposal methods: When waste materials and waste water are to be treated, collect them into specified containers and entrust the disposal to a disposal contractor having an industrial waste disposal contractor permit. Do not use the used containers for other purposes like filling other substances. Be sure to dispose of them after treating the content according to the above description. In case of recycling the container, return the container as it is after fitting a stopper without filling anything into it.