Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 Nov 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP - guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT187
GLP compliance:
yes (incl. QA statement)
Remarks:
LUBW Landesanstalt für Umwelt, Messungen und Naturschutz Baden-Württemberg, Karlsruhe, Germany
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
>= 73.3 - <= 79 µm
Percentile:
D10
Mean:
9.82 µm
Remarks on result:
other: Two measurements done. St. dev. not possible to determined.
Percentile:
D50
Mean:
76.2 µm
Remarks on result:
other: Two measurements done. St. dev. not possible to determined.
Percentile:
D90
Mean:
350 µm
Remarks on result:
other: Two measurements done. St. dev. not possible to determined.
No.:
#1
Size:
< 10 µm
Distribution:
10.2 %

The results were obtained using 3.5 bar dispersing energy and a feed rate of 50 %.

Particle Size Distribution of Ammonium Niobium Oxalate

 

Measurement 1

Measurement 2

Mean

L10D (v,0.1):

9.79 µm

9.85 µm

9.82 µm

L50D (v,0.5):

79.0 µm

73.3 µm

76.2 µm

L90D (v,0.9):

363 µm

337 µm

350 µm

particle < 10 µm (v,%):

10.2 %

10.2 %

10.2 %

Description of key information

MMAD: 73.3 - 79.0 µm (mean MMAD 76.2 µm) (CIPAC MT187)

Additional information

The particle size distribution of the test item was determined by laser diffraction according to CIPAC method MT187.