Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Remarks:
Peer-reviewed assessment report (attached in section 13)
Reference:
Composition 0
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
other: not further specified
Test material information:
Composition 1
Specific details on test material used for the study:
Purity: 98.6%
Flash point:
>= 148 - <= 152 °C
Remarks on result:
other: no information on atm. pressure available, but standard pressure can be assumed
Interpretation of results:
GHS criteria not met
Conclusions:
As information was provided via a peer-reviewed assessment report, it can be considered as sufficiently reliable. The flash point was determined to be 150°C ± 2°C.
Executive summary:

In a GLP test according to EU Method A.9 a flash point of 150 ± 2°C has been determined.

Description of key information

The flash point was determined to be 150°C ± 2°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
150 °C

Additional information