Administrative data

Endpoint:
skin irritation / corrosion
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment

Data source

Reference
Reference Type:
publication
Title:
Range-Finding Toxicity data List V
Author:
Smyth Jr H.F., Carpenter C.P., Weil C.S., Pozzani U.C.
Year:
1954
Bibliographic source:
AMA Arch. Ind. Hyg. Occup. Med. 10, 61-68 (1954)

Materials and methods

Principles of method if other than guideline:
The primary skin irritation potential of the test substance was assessed on 5 albino rabbits within 24 hours of application.
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
3,3'-(methylimino)bispropiononitrile
EC Number:
216-305-9
EC Name:
3,3'-(methylimino)bispropiononitrile
Cas Number:
1555-58-4
Molecular formula:
C7H11N3
IUPAC Name:
3-[(2-cyanoethyl)(methyl)amino]propanenitrile
Test material form:
liquid
Specific details on test material used for the study:
- Name as used in publication: N-Methyl-3,3'-iminodipropionitrile

Test animals

Species:
rabbit
Strain:
other: Albino not further specified

Test system

Type of coverage:
occlusive
Preparation of test site:
clipped
Vehicle:
other: Undiluted, water, propylene glycol, or kerosene
Controls:
no
Amount / concentration applied:
0.01 mL in concentrations ranging from 0.01 % to 100%
Duration of treatment / exposure:
24 hours
Observation period:
24 hours
Number of animals:
5
Details on study design:
SCORING SYSTEM:Effects were graded on a scale from 1 to 10. Grade 1 indicates the least visible capillary injection from undiluted chemical. Grade 6 indicate necrosis when undiluted. Grade 10 indicates necrosis from a 0.01 % solution.

Results and discussion

In vivo

Results
Irritation parameter:
other: Grade
Basis:
mean
Time point:
24 h
Score:
1
Max. score:
10
Remarks on result:
no indication of irritation
Irritant / corrosive response data:
The test substance scored grade 1 out of 10. Indicating the least visible capillary injection from undiluted chemical.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met