Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental start date 25 September 2017. Experimental completion date 26 September 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Identification: Pigment Red 81:4
CAS Number: 85959-61-1
Physical state/Appearance: red powder
Batch: 64078
Purity: not provided
Expiry Date: 1 November 2017
Storage Conditions: room temperature in the dark
Vehicle:
no
Details on test solutions:
In the range-finding test, activated sewage sludge micro-organisms were exposed to a series of nominal test concentrations of 10, 100 and 1000 mg/L. The test item was dispersed directly in water.
Nominal amounts of test item (5, 50 and 500 mg (500 mg in triplicate)) were each separately dispersed in approximately 200 mL of deionized reverse osmosis water and subjected to ultrasonication for approximately 15 minutes followed by magnetic stirring for 24 hours, at room temperature, in order to maximize the dissolved test item concentration. All test vessels were shielded from the light during mixing. Synthetic sewage (16 mL), activated sewage sludge (250 mL) and water were added to a final volume of 500 mL to give the required concentrations of 10, 100 and 1000 mg/L (3 replicates).
The pH of the test item dispersions was measured after stirring using a Hach HQ40d Flexi handheld meter and adjusted to between pH 7.0 and 8.0 if necessary.
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
A mixed population of activated sewage sludge micro-organisms was obtained on 25 September 2017 from the aeration stage of the Severn Trent Water Plc sewage treatment plant at Loughborough, Leicestershire, UK which treats predominantly domestic sewage.

Preparation of Inoculum
The activated sewage sludge sample was maintained on continuous aeration in the laboratory at a temperature of approximately 21 ºC overnight prior to use in the test. On the day of collection the activated sewage sludge (8 liters) was fed synthetic sewage (400 mL). The pH of the sample on the day of the test was 7.3 measured using a Hach HQ40d Flexi handheld meter. Determination of the suspended solids level of the activated sewage sludge was carried out by filtering a sample (100 mL) of the activated sewage sludge by suction through a pre-weighed GF/A filter paper using a Buchner funnel which was then rinsed 3 times with 10 mL of deionized reverse osmosis water and filtration continued for 3 minutes. The filter paper was then dried in an oven at approximately 105 ºC for at least one hour and allowed to cool before weighing. This process was repeated until a constant weight was attained. The suspended solids concentration was equal to 3.0 g/L prior to use.
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Test temperature:
The test was conducted in a temperature controlled room at measured temperatures of approximately 20 ºC.
pH:
The pH of test preparations was measured at the test start (i.e. after the addition of activated sludge) and at the end of the 3-Hour incubation period using a Hach HQ40d Flexi handheld meter
Dissolved oxygen:
The oxygen concentrations in all vessels were measured after 30 minutes contact time.
The dissolved oxygen concentrations after 30 minutes contact time in all vessels were above 60% of the dissolved oxygen saturation level of 8.9 mg O2/L.
Nominal and measured concentrations:
Nominal test concentrations of 10, 100 and 1000 mg/L.
As it was not a requirement of the Test Guidelines, no analysis was conducted to determine the homogeneity, concentration or stability of the test item formulation. This is an exception with regard to GLP and has been reflected in the GLP compliance statement.
Details on test conditions:
Preparation of Test System
At time "0" 16 mL of synthetic sewage was diluted to 250 mL with water and 250 mL of inoculum added in a 500 mL conical flask (first control). The mixture was aerated with clean, oil-free compressed air via narrow bore glass tubes at a rate of 0.5 to 1.0 liter per minute. Thereafter, at 15 minute intervals the procedure was repeated for the second control followed by the reference item vessels with appropriate amounts of the reference item being added. The test item vessels were prepared as described in details on test solution section. Finally two further control vessels were prepared.
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Key result
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Key result
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
Range-Finding Test
No statistically significant toxic effects were shown at any of the test concentrations employed. It was therefore considered justifiable not to perform a definitive test.
It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/L.

Inhibition of Respiration Rate
In some instances, the initial and final dissolved oxygen concentrations were outside those recommended in the test guidelines (7 mg O2/L and 2 mg O2/L respectively). This was considered to have had no adverse effect on the results of the study given that in all cases the oxygen consumption rate was determined over the linear portion of the oxygen consumption trace.
Results with reference substance (positive control):
The positive control gave the following results:
EC10: 1.2 mg/L
EC20: 1.9 mg/L
EC50: 6.7 mg/L (95% confidence limits 5.1 - 5.8 mg/L)
EC80: 24 mg/L

Oxygen Consumption Rates and Percentage Inhibition Values after 3 Hours Contact Time in the Range-Finding Test

Nominal
Concentration
(mg/L)
Initial
O2 Reading
(mg O2/L)
Measurement
Period
(minutes)
Final O2
Reading
(mg O2/L)
O2
Consumption
Rates
(mg O2/L/hour)
%
Inhibition
Control R1 4.1 3 1.8 46 -
R2 4.7 4 1.7 45 -
R3 5.1 4 1.9 48 -
R4 4.7 3 2.2 50 -
Test item 10 5 3 2.4 52 [10]
100 5 3 2.5 50 [6]
1000 R1 4.9 4 2.1 42 11
1000 R2 4.6 4 1.6 45 5
1000 R3 4.8 4 2 42 11
3,5-
dichlorophenol
3.2 6.5 8 2.3 31.5 33
10 7.3 10 4.1 19.2 59
32 8.3 10 7.3 6 87

R1 – R4 = Replicates 1 to 4

[Increase in respiration rate as compared to controls]

Validity criteria fulfilled:
yes
Conclusions:
The effect of the test item on the respiration of activated sewage sludge micro-organisms gave a 3-Hour EC50 value of greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/L.
Executive summary:

Introduction

A study was performed to assess the effect of the test item on the respiration of activated sewage sludge. The method followed was designed to be compatible with the OECD Guidelines for Testing of Chemicals (2010) No. 209 "Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation)".

Methods

Activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 10, 100 and 1000 mg/L (3 replicates of the 1000 mg/L test concentration) for a period of 3 hours at measured temperatures of approximately 20 °C with the addition of a synthetic sewage as a respiratory substrate.

The rate of respiration was determined after 3 hours contact time and compared to data for the control and a reference item, 3,5-dichlorophenol.

Results

The effect of the test item on the respiration of activated sewage sludge gave a 3-Hour EC50 value of greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/L.

It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/L.

The reference item gave a 3-Hour EC50 value of 6.7 mg/L, 95% confidence limits 5.1 to 8.8 mg/L.

Description of key information

The effect of the test item on the respiration of activated sewage sludge micro-organisms gave a 3-Hour EC50 value of greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/L.

Key value for chemical safety assessment

EC10 or NOEC for microorganisms:
1 000 mg/L

Additional information

Introduction

A study was performed to assess the effect of the test item on the respiration of activated sewage sludge. The method followed was designed to be compatible with the OECD Guidelines for Testing of Chemicals (2010) No. 209 "Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation)".

Methods

Activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 10, 100 and 1000 mg/L (3 replicates of the 1000 mg/L test concentration) for a period of 3 hours at measured temperatures of approximately 20 °C with the addition of a synthetic sewage as a respiratory substrate.

The rate of respiration was determined after 3 hours contact time and compared to data for the control and a reference item, 3,5-dichlorophenol.

Results

The effect of the test item on the respiration of activated sewage sludge gave a 3-Hour EC50 value of greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/L.

It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/L.

The reference item gave a 3-Hour EC50 value of 6.7 mg/L, 95% confidence limits 5.1 to 8.8 mg/L.