Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
yes
Analytical monitoring:
no
Vehicle:
no
Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Activated sludge from laboratory wastewater plant treating municipal sewage.
- The inoculum was washed, brought to a concentration of 5 g/L dry substance and aerated during the night.
- 50 mL were added to a total volume of 250 mL to obtain a concentration of 1 g/L dry substance in the test.
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
30 min
Test temperature:
20+/-2°C
Dissolved oxygen:
- During aeration: >2.5 mg/L
- Immediately before measurement: >6.5 mg/L
Nominal and measured concentrations:
- Nominal concentrations of test substance (mg/L): 10, 100, 248, 496, 1000
Details on test conditions:
- Test vessels: Erlenmeyer-vessels (nominal volume 250 mL)
- Test volume: 250 mL
- Synthetic medium: 8 mL/vessel 100-fold concentrated OECD
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Duration:
30 min
Dose descriptor:
other: EC20
Effect conc.:
ca. 170 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Key result
Duration:
30 min
Dose descriptor:
EC50
Effect conc.:
ca. 550 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
30 min
Dose descriptor:
other: EC80
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Results with reference substance (positive control):
- EC50 of 3,5-dichlorophenol in the range of 5-30 mg/L
- Deviation of blank controls < 15%

Description of key information

The test substance was tested in an OECD guideline study. The EC50 was determined to be 550 mg/L.

Key value for chemical safety assessment

EC50 for microorganisms:
550 mg/L

Additional information

Freshwater

Key

The test substance was tested in an OECD guideline 209 study. The nominal concentrations tested were 10, 100, 248, 496, 1000 mg/L.The test was conducted under static conditions. Domestic activated sludge was used as inoculum. The total exposure duration was 30 min. The EC50 was determined to be 550 mg/L.

Supporting

The toxicity to microorganisms was tested in a study according to DIN 38412-8. The nominal concentration (mg/L) used were: 39.06, 78.13, 156.25, 312.5, 625, 1250, 2500, 5000, 10000. The EC50 value was determined to be 55.4 mg/L and the EC10 value was determined to be 41.3 mg/L. Both values based on growth inhibition.

The toxicity to microorganisms was tested in this OECD guideline study. The test substance was tested under static conditions with a total exposure duration of 30 min. The EC50 value was determined to be 560 mg/l.

The toxicity to microorganisms was tested in this OECD guideline study. Only few data were available for this study. The EC50 value was determined to be 370 mg/L and the EC10 value was determined to be 140 mg/L.

Conclusion: 4 different studies were available. 3 OECD guideline studies were available one study according to DIN 38412 -8. The results of the guideline studies lay all in the same range. As a result the EC50 value of 550 mg/L was chosen as key result.