Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning time (test type not further specified)
Burning time:
20 s
Remarks on result:
other: Rate of burning (over 200 mm) - Classification of substance: Highly Flammable

Rate of burning (over 200 mm): 20 seconds

Rate of burning (over 100 mm): 11 seconds

Interpretation of results:
highly flammable
Remarks:
Migrated information
Conclusions:
In a study performed to EU Method A.10, ferrocene has a rate of burning (over 200 mm) of 20 secs. It is therefore classified as highly flammable

Description of key information

Ferrocene has a rate of burning (over 200 mm) of 20 secs, and is therefore classified as a highly flammable solid

Key value for chemical safety assessment

Flammability:
highly flammable

Additional information

In a study performed to EU Method A.10, ferrocene has a rate of burning (over 200 mm) of 20 secs. It is therefore classified as a highly flammable solid

Justification for classification or non-classification

In a study performed to EU Method A.10, ferrocene has a rate of burning (over 200 mm) of 20 secs. It is therefore classified as a highly flammable solid according to CLP and it will carry the labelling Flammable Solid, Category 1 and according to DSD it will carry F;R11, Highly Flammable