Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study according to national/international standards

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: DIN 66165: Sieve analysis - dry-sieving; sieves DIN/ISO 3310
Principles of method if other than guideline:
Dry sieving at various pore sizes under vibration, one of the least destructive techniques, was used.
GLP compliance:
not specified
Type of distribution:
other:

Test material

Constituent 1
Chemical structure
Reference substance name:
Carbazole
EC Number:
201-696-0
EC Name:
Carbazole
Cas Number:
86-74-8
Molecular formula:
C12H9N
IUPAC Name:
9H-carbazole
Details on test material:
- Name of test material (as cited in study report): Reincarbazol 97%
- Substance type: organic
- Physical state: solid
- Analytical purity: 97 %

Results and discussion

Particle size
Percentile:
D50
Mean:
ca. 700 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
Size:
400 µm
Distribution:
<= 19.2 %
Size:
800 µm
Distribution:
<= 63.5 %
Size:
1 000 µm
Distribution:
<= 79.2 %
Size:
2 000 µm
Distribution:
<= 99.2

Any other information on results incl. tables

The sizes given above refer to the upper pore sizes of the sieves applied.

Applicant's summary and conclusion