D50=179.23µm, laser diffraction, Füldner 2003
MMAD=248.5µm, air elutriation, Rattray 2004

Additional information

The median particle size determined by laser diffraction was 179.23µm (Füldner 2003). The mass median aerodynamic diameter determined by air elutriation (Rattray 2004) was extrapolated to be 248.5µm. The material tested was not considered to be respirable, and of low inhalability.