Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
Reliability was rated as 2 because viscosity of test substance was determined using ASTM D-445 method and was not carried under GLP. However, the methodology for viscosity determination is commonly used in the US lubricant industry and is considered scientifically sound and acceptable. The ASTM method is similar or equivalent to the OECD or EPA test methods.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D-445
Principles of method if other than guideline:
Summary of ASTM D-445 method: The time is measured for a fixed volume of liquid to flow under gravity through the capillary of a calibrated viscometer under a reproducible driving head and at a closely controlled and known temperature. The determined kinematic viscosity value is the product of the measured flow time and the calibration constant of the viscometer.
GLP compliance:
no
Remarks:
Test was compliant with ASTM method
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Reference substance name:
MCP 2484 (Synesstic 12)
IUPAC Name:
MCP 2484 (Synesstic 12)

Results and discussion

Viscosity
Temp.:
other: 100.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
12

Applicant's summary and conclusion

Conclusions:
The viscosity of the test material was reported to be 12 cst at 100 degree C using the ASTM D-445 method