Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From June 8, 2011 to December 2, 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study was performed according to the EC A.6 Guideline without GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
no
GLP compliance:
no
Remarks:
The laboratory is working according to its own Quality System externally auditer but it is not the GLP Quality System.
Type of method:
flask method
Water solubility:
0.104 g/L
Temp.:
20 °C
pH:
> 4.01 - < 4.27
Remarks on result:
other: Uncertainty ± 0.034

In the water solubility study of the substance, a micro-emulsion or suspension of the substance is formed showing some turbidity. A turbidimeter was employed to semi-quantify the point at which a test substance might no longer be deemed to be truly in solution. An arbitrary figure of 10 NTU’s (Nephelometric Turbidity Units) was selected as a figure above which the solution is deemed to be visible cloudy and the test substance is no longer fully disolved. Turbidity and Chemical Oxygen Demand (COD) were measured in test solutions.

Conclusions:
Interpretation of results (migrated information): moderately soluble (100-1000 mg/L)
Water solubility of the test material determined at 20.0 ± 0.5 ºC was 0.104 ± 0.034 g/L.
Executive summary:

Water solubility of the test material has been determinated according to the EC A.6 test Guideline. No signs of degradation have been observed in the measurements carried out in the pH of the solution (in a range of 4.01 - 4.27) at 24, 48 and 72 hours. Water solubility of the test material determined at 20.0 ± 0.5 ºC was 0.104 ± 0.034 g/L.

Description of key information

Key study: EC Guideline A.6. No GLP study. Water solubility was 0.104 ± 0.034 g/L at 20.0 ± 0.5ºC.

Key value for chemical safety assessment

Water solubility:
0.104 g/L
at the temperature of:
20 °C

Additional information

Key study: Experimental result on test item Reaction products of n-octanol and acrylic acid, first distillation pitch:

Water Solubility of the test substance was carried out according to the EC A.6. Guideline (without GLP) and was determinated to be 0.104 ± 0.034 g/L at 20.0 ± 0.5 ºC.