Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 4, 2007- January 19, 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD and EU guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Corsair Resin 5
- Substance type: UVCB
- Physical state: beige solid granules
- Stability under test conditions: stable
- Storage condition of test material: At room temperature in the dark

Results and discussion

Density
Type:
relative density
Density:
0.96
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
An air comparison pycnometer was used for the determination of the density and relative density of Corsair Resin 5. The density of the test substance was 0.963 g/cm3 (0.963 x 103 kg/m3). The relative density was 0.963.