Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1989, november 20th
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study performed according to the Test Guidelines described in the EEC Directive 84/449/EEC

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1989
Report date:
1989

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
3',5'-dichloro-4'-ethyl-2'-hydroxypalmitanilide
EC Number:
406-200-8
EC Name:
3',5'-dichloro-4'-ethyl-2'-hydroxypalmitanilide
Cas Number:
117827-06-2
Molecular formula:
C24H39Cl2NO2
IUPAC Name:
N-(3,5-dichloro-4-ethyl-2-hydroxyphenyl)hexadecanamide
Details on test material:
UC-136
White powder
Purity 98.5%
Storage conditions: at room temperature in the dark in a tighly sealed container
Stability of test substance: stable for one year maximal under storage conditions
Expiry date: january 5, 1990
Safety precautions: gloves and goggles were used to assure personnel health and safety
The test was performed in a fume cupboard.

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
UC-136 could not be ignited with a flame