Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22.07.2022 to 22.07.2022
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)
Key result
Parameter:
sensitiveness to friction: friction load (N)
Value:
120
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
mm
Value:
2
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
mm
Value:
6
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Value:
40
Conclusions:
The test item has no explosive properties according to the EC A.14 method criteria.
Executive summary:

The determination of the explosive properties of the test item was performed in accordance to EC A.14 guidelines, under GLP conditions.


A determination of impact sensitivity, thermal sensitivity and friction sensitivity were permormed.


Therefore, it was determined that the test item has no explosive properties.

Description of key information

Key study. Study was performed in accordance to EC A.14 guidelines, under GLP conditions. It was determined that the test item has no explosive properties.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

Based on available data, the substance is not expected to be classified for explosive properties in accordance with CLP Regulation (EC) no. 1272/2008.