Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 1999-07-06 to 1999-07-13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
thermal sensitivity - Koenen test: limiting diameter (mm)
Remarks on result:
not thermal sensitive if heated under defined confinement

Thermal Stability (Steel Cartridge Test)


Method: Koenen test as described in EC Guideline A14.


 


Koenen test results









































Nozzle Diameter



Reaction Initiation after



Results



2 mm



49 s



No fragments, cartridge unchanged



2 mm



50 s



No fragments, cartridge unchanged



2 mm



52 s



No fragments, cartridge unchanged



6 mm



58 s



No fragments, cartridge unchanged



6 mm



60 s



No fragments, cartridge unchanged



6 mm



58 s



No fragments, cartridge unchanged



The test item is not explosive when heated under defined confinement as stipulated by EC Guideline A 14.


 


Mechanical Sensitivity (Drop-Weight Test)


Method: BAM drop-weight test as described in the EC Guideline.


 


Drop-weight test results









































Mass



Drop Height



Results



10 kg



40 cm



Negative; no optical change in product apparent



10 kg



40 cm



Negative; no optical change in product apparent



10 kg



40 cm



Negative; no optical change in product apparent



10 kg



40 cm



Negative; no optical change in product apparent



10 kg



40 cm



Negative; no optical change in product apparent



10 kg



40 cm



Negative; no optical change in product apparent



The test item is not sensitive to shock when tested according to EC Guideline A 14


 


Mechanical Sensitivity (Friction Mill)


Method: BAM friction mill as described in EC Guideline A 14


Pin pressure: 360 N


Result Six times negative


The test item is not sensitive to friction when tested according to EC Guideline A 14.


 


The test item is not explosive in the sense of EC Guideline A 14

Interpretation of results:
GHS criteria not met
Conclusions:
The test item is not considered to have explosive properties.
Executive summary:

A study was conducted according to EU Method A.14. The thermal sensitivity, the mechanical sensitivity to shock and the mechanical sensitivity to friction was investigated. No explosive properties were observed under the test conditions. Therefore, the item is not considered to have explosive properties.

Description of key information

The test item is not considered to have explosive properties.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

A study was conducted according to EU Method A.14. The thermal sensitivity, the mechanical sensitivity to shock and the mechanical sensitivity to friction was investigated. No explosive properties were observed under the test conditions. Therefore, the item is not considered to have explosive properties.

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No 1272/2008
Based on the structure of the molecule and taking into account the provisions laid down in Regulation (EC) No 1272/2008 (CLP), as amended for the seventeenth time in Regulation (EU) 2021/849, the test item does not have to be classified with respect to explosiveness.