Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 866-700-0 | CAS number: 2102522-55-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 9 May 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
- Version / remarks:
- 22 July 2010
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- Identification and stability under storage conditions: The infrared (IR) spectrum of the test material measured at the test facility was confirmed to be identical to that provided by the sponsor. The stability of the test material was confirmed by comparing the IR spectrum of the test material after the completion of the experiment with that before the start of the experiment.
The test material was treated as 100% in purity. - Analytical monitoring:
- no
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION
- Test mixture: The test material (250 mg), the synthetic sewage (8 mL), purified water (117 mL) and the activated sludge (125 mL) were added to each test vessel. The test material was accurately weighed with an electric analytical balance and added. The pH of the test solution of the test material was not measured because the test material was not dissolved in test solutions.
- Reference mixture: 1000 mg/L stock solution of 3,5-dichlorophenol, the synthetic sewage (8 mL), activated sludge (125 mL) and purified water.
- Blank control: Synthetic sewage (8 mL), activated sludge (125 mL) and purified water. - Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Name and location of sewage treatment plant where inoculum was collected: The activated sludge obtained from an aeration reactor of a sewage treatment plant receiving predominantly domestic sewage from Kurume central sewage treatment centre (Kurume-shi, Fukuoka, Japan)
- Method of cultivation: The activated sludge (5 L) was fed with the synthetic sewage (250 mL) and cultivated for 22 hours at 20 ± 2 °C under aerobic condition in order to acclimate the test temperature. The activated sludge was then used. Acclimation to the test material was not performed.
- Preparation of inoculum for exposure: The synthetic sewage (500 mL) was prepared at the same proportion as follows: the following reagents were dissolved in 1 L of purified water.
1) Peptone 16 g
2) Meat extract 11 g
3) Urea 3 g
4) Sodium chloride 0.7 g
5) Calcium chloride dihydrate 0.4 g
6) Magnesium sulfate heptahydrate 0.2 g
7) Dipotassium hydrogen phosphate 2.8 g
The pH of the prepared synthetic sewage was 7.2. The synthetic sewage was prepared the day before the test and was stored in a refrigerator until use. - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- yes
- Total exposure duration:
- 3 h
- Test temperature:
- 20 ± 2 °C
- pH:
- The pH of the reference mixture and blank control was measured and confirmed to be within 7.5 ± 0.5.
- Nominal and measured concentrations:
- 1000 mg/L as nominal loading concentration
- Details on test conditions:
- TEST SYSTEM
- Test vessel: Approximately 300 mL glass vessel
- Fill volume: 250 mL
- Measurement bottle: 102 mL glass incubator bottle
- Aeration: 0.5–1 L/min (Air pump)
- No. of vessels per concentration (replicates): 3
- No. of vessels per control (replicates): 6 (3 replicates at the beginning and the end of the exposure period in the test, individually).
- Sludge concentration (concentration of suspended solids): 2760 mg/L
EFFECT PARAMETERS MEASURED
Measurement of dissolved oxygen concentration to calculate oxygen consumption rate: After 3 hours of exposure, the measurement bottle was filled with the test solution promptly and softly with attention to avoid foaming. Afterwards, the concentration of dissolved oxygen (DO) in the test solution was measured continuously for 10 minutes with stirring.
TEST CONCENTRATIONS
- Range finding study: In the preliminary test, three test concentrations of the test material at 10, 100 and 1000 mg/L were prepared, and their percentages of respiration inhibition were -6 %, -10 % and 22 %, respectively, after 3 hours of exposure. The results suggested that EC50 of the test material was higher than 1000 mg/L. Therefore, the test mixture was prepared as a limit test.
- Test concentrations: 1000 mg/L (nominal loading concentration)
- Results used to determine the conditions for the definitive study: Yes.
ESTIMATION OF EC50
- Calculation of percentage inhibition of respiration: solution, and a regression formula was derived from the linear part in the graph. The oxygen consumption rate (mgO2/L/h) was obtained from the absolute value of slope of the regression formula. The percentage inhibition of respiration was then calculated by the following equation:
Percentage inhibition of respiration (%) = (1-RS/RC ) × 100
RS : Oxygen consumption rate in test or reference mixture (mg O2/L/h)
RC : Average oxygen consumption rate in blank control (mg O2/L/h)
- Estimation of EC50: In the test mixture, the EC50 of the test material was estimated as " >1000 mg/L" because less than 50 % of inhibition rate was obtained within the exposure level. In the reference mixture, the percentage inhibition in each exposure level was plotted on a semilogarithmic graph against the corresponding concentration. The EC50 of the reference substance (3,5-dichlorophenol) was calculated from the regression formula obtained by probit analysis. The EC50 was determined using computer program (running on Microsoft software "Excel").
VALIDITY CRITERIA
- The EC50 of 3,5-dichlorophenol as reference item should be between 2–25 mg/L
- The coefficient of variation of the oxygen consumption rate in the blank controls between at the beginning and at the end of the exposure period should be less than 30%
- The oxygen consumption rate per gram (dry weight) of activated sludge per hour in the blank control should be ≥20 mg O2/g/h
Oxygen consumption rate (mg O2/g/h) = [(RC × V) / (SS × VS)] × 1000
RC : Average oxygen consumption rate in blank control (mg O2/L/h)
V : Volume of test solution (L)
SS : Concentration of suspended solid in activated sludge (mg/L)
VS : Additive amount of activated sludge (L) - Reference substance (positive control):
- yes
- Remarks:
- 3,5-dichlorophenol, 4.0, 8.0, 16 and 32 mg/L (geometric series with a factor of 2), 1 replicate/exposure level.
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Details on results:
- PRELIMINARY TEST
- Three test concentrations of the test material at 10, 100 and 1000 mg/L were prepared, and their percentages of respiration inhibition were -6 %, -10 % and 22 %, respectively, after 3 hours of exposure. The results suggested that EC50 of the test material was higher than 1000 mg/L, therefore the test mixture was prepared as a limit test.
MAIN TEST
- Average oxygen consumption rate in blank control: 47.9 mg O2/L/h.
- The average percentage inhibition of respiration of the test mixture at 1000 mg/L was 5 %.
VALIDITY OF TEST
The test was valid because the test results met the following criteria:
- The EC50 of 3,5-dichlorophenol as reference item was 11 mg/L this value met the criterion (2–25 mg/L).
- The coefficient of variation of the oxygen consumption rate in the blank controls between at the beginning and at the end of the exposure period was 4.8 %, and this value met the criterion (less than 30%).
- The oxygen consumption rate per gram (dry weight) of activated sludge per hour in the blank control was average 34.7 mgO2/g/h, and this value met the criterion (≥20 mg O2/g/h). - Results with reference substance (positive control):
- A stock solution of the reference substance was prepared, 3,5-dichlorophenol (100 mg) was accurately weighed with an electronic analytical balance and dissolved in approximately 80 mL of purified water. The pH of this solution was adjusted to 7.5 with 1 mol/L sodium hydroxide solution. And then, this solution was filled up to 100 mL by purified water to obtain 1000 mg/L stock solution of 3,5-dichlorophenol.
The following concentrations of the reference mixture were tested: 4.0, 8.0, 16 and 32 mg/L (geometric series with a factor of 2) with 1 replicate per exposure level. At the nominal concentrations of 4.0, 8.0, 16 and 32 mg/L the oxygen consumption rate was 38.9, 34.6, 16.9 and 5.18 mg O2/L/h respectively. The EC50 was determined to be 11 mg/L. - Validity criteria fulfilled:
- yes
- Conclusions:
- Under the conditions of this study the average percentage inhibition of respiration of the test mixture at 1000 mg/L was 5 %, therefore the EC50 of the test material was estimated as >1000 mg/mL (as nominal loading concentration).
- Executive summary:
To determine the 3-hour EC50 of the test material an activated sludge respiration inhibition test was conducted in accordance with the standardised guidelines OECD 209, under GLP conditions.
In the preliminary test, three test concentrations of the test material at 10, 100 and 1000 mg/L were prepared, and their percentages of respiration inhibition were -6 %, -10 % and 22 %, respectively, after 3 hours of exposure. The results suggested that EC50 of the test material was higher than 1000 mg/L. Therefore, the test mixture was prepared as a limit test, and the test concentration of the test material was carried out at 1000 mg/L as nominal loading concentration. The reference mixture used was 3,5-Dichlorophenol. After 3 hours of exposure, the measurement bottle was filled with the test solution promptly and softly with attention to avoid foaming. Afterwards, the concentration of dissolved oxygen DO) in the test solution was measured continuously for 10 minutes with stirring. The activated sludge was obtained from the aeration reactor of the sewage treatment plant receiving predominantly domestic sewage. This test was valid because all of the values in this test met the criteria. The EC50 of the reference substance was determined to be 11mg/L.
Under the conditions of this study the average percentage inhibition of respiration of the test mixture at 1000 mg/L was 5 %, therefore the EC50 of the test material was estimated as >1000 mg/mL (as nominal loading concentration).
Reference
Oxygen consumption rate and percentage inhibition of respiration after 3 hours of exposure
Test solution |
Nominal loading concentration (mg/L) |
Oxygen consumption rate (mg O2/L/h) |
Percentage inhibition of respiration (%) |
Average percentage inhibition of respiration (%) |
Test mixture |
1000 1000 1000 |
42.6 49.8 43.6 |
11 -4 9 |
5 |
Reference mixture |
4.0 8.0 16 32 |
38.9 34.6 16.9 5.18 |
19 28 65 89 |
- |
Blank control |
- |
At the beginning: 42.5, 47.9, 48.3 At the end: 45.1, 52.0, 51.4 |
- |
- |
Average oxygen consumption rate in blank control: 47.9 mg O2/L/h
Description of key information
The average percentage inhibition of respiration of the test mixture at 1000 mg/L was 5 %, therefore the EC50 of the test material was estimated as >1000 mg/mL (as nominal loading concentration).
Key value for chemical safety assessment
- EC50 for microorganisms:
- 1 000 mg/L
Additional information
To determine the 3-hour EC50 of the test material an activated sludge respiration inhibition test was conducted in accordance with the standardised guidelines OECD 209, under GLP conditions. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).
In the preliminary test, three test concentrations of the test material at 10, 100 and 1000 mg/L were prepared, and their percentages of respiration inhibition were -6 %, -10 % and 22 %, respectively, after 3 hours of exposure. The results suggested that EC50 of the test material was higher than 1000 mg/L. Therefore, the test mixture was prepared as a limit test, and the test concentration of the test material was carried out at 1000 mg/L as nominal loading concentration. The reference mixture used was 3,5-Dichlorophenol. After 3 hours of exposure, the measurement bottle was filled with the test solution promptly and softly with attention to avoid foaming. Afterwards, the concentration of dissolved oxygen DO) in the test solution was measured continuously for 10 minutes with stirring. The activated sludge was obtained from the aeration reactor of the sewage treatment plant receiving predominantly domestic sewage. This test was valid because all of the values in this test met the criteria. The EC50 of the reference substance was determined to be 11mg/L.
Under the conditions of this study the average percentage inhibition of respiration of the test mixture at 1000 mg/L was 5 %, therefore the EC50 of the test material was estimated as >1000 mg/mL (as nominal loading concentration).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.