Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 July 2019 to 01 July 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
No further details specified in the study report
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
2 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

In the preliminary tests the test item melted. The molten test item flamed for 1-2 seconds, but did not propagate further, then the flame extinguished itself.

Based on the results of the preliminary tests, no main test was performed.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The molten test item flamed for 1-2 seconds, but did not propagate. Therefore, the test item is considered to be non-flammable.
Executive summary:

The flammability of test item CAS 577978-76-8 was carried out in accordance with test guideline EU A.10, in compliance with GLP.

Two parallel flammability tests were performed. The tests were negative.

The test item (CAS 577978-76-8) is considered to be non-flammable under the conditions of this test.

Description of key information

The molten test item flamed for 1-2 seconds, but did not propagate. Therefore, the test item is considered to be non-flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The molten test item flamed for 1-2 seconds, but did not propagate. Therefore, the test item is considered to be non-flammable.