Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-12-09 (Study Plan Verification) - 2017-06-28 (final report)
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Version of 2008-05-30
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Remarks:
Setaflash 30000-0 flash point tester
Key result
Flash point:
>= 103 - <= 107 °C
Atm. press.:
102.7 kPa
Key result
Flash point:
104.7 °C
Atm. press.:
102.7 kPa
Remarks on result:
other: corrected flash point

Results

Results of the flash point determination are shown in the following table:

Table 1

Test temperature (°C)

Observations

22.0

No flash.

27.0

No flash.

32.0

No flash.

37.0

A blue flash spread across the sample cup.

37.0 (fresh sample)

No flash.

42.0

No flash.

47.0

No flash.

52.0

No flash.

57.0

No flash.

62.0

No flash.

67.0

No flash.

72.0

No flash.

77.0

No flash.

82.0

No flash.

87.0

No flash.

87.0 (fresh sample)

No flash.

92.0

No flash.

97.0

No flash.

102.0 (fresh sample)

No flash.

107.0

A blue flash spread across the sample cup.

107.0 (fresh sample)

A blue flash spread across the sample cup.

102.0 (fresh sample)

No flash.

103.0 (fresh sample)

No flash.

104.0 (fresh sample)

No flash.

105.0 (fresh sample)

A blue flash spread across the sample cup.

105.0 (fresh sample)

A blue flash spread across the sample cup.

103.0 (fresh sample)

No flash.

Atmospheric pressure: 102.7 kPa

Corrected flash point: 104.7 ºC

Conclusion

The flash point of the test item has been determined to be 105 ± 2 °C.

Interpretation of results:
other: EU GHS criteria not met
Conclusions:
The flash point of the test item has been determined to be 105 ± 2 °C.
Executive summary:

Flash Point. 105 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008

Description of key information

Flash Point. 105 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008

Key value for chemical safety assessment

Flash point at 101 325 Pa:
105 °C

Additional information