First-aid measures

General advice : Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled : If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

In case of skin contact : Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Consult a physician.

In case of eye contact : Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

If swallowed : Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Fire-fighting measures

Suitable extinguishing media : Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Special hazards arising from the substance or mixture : Carbon oxides, Sulphur oxides, Hydrogen fluoride, silicon oxides

Advice for firefighters : Wear self-contained breathing apparatus for firefighting if necessary.

Accidental release measures

Personal precautions, protective equipment and emergency procedures :

Use personal protective equipment. Avoid breathing vapours, mist or gas. Ensure adequate ventilation.

Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to

form explosive concentrations. Vapours can accumulate in low areas.

Environmental precautions :

Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

Methods and materials for containment and cleaning up :

Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and

place in container for disposal according to local regulations (see section 13).

Handling and storage

Precautions for safe handling :

Avoid contact with skin and eyes. Avoid inhalation of vapour or mist.

Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic charge

Conditions for safe storage, including any incompatibilities :

Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Recommended storage temperature 2 - 8 °C

This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 18(4) for transported isolated intermediate. Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management system is available at each site. Written confirmation of application of Strictly Controlled Conditions has been received from every Downstream user of the intermediate.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
2920
Shippingopen allclose all
Labels:
8+3
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
2920
Shippingopen allclose all
Labels:
8+3
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
2920
Shipping information
Proper shipping name and description:
Corrosive liquid, flammable, n.o.s.
Labels:
8+3
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
2920
Shipping information
Proper shipping name and description:
Corrosive liquid, flammable, n.o.s.
Labels:
8+3
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Eye/face protection :

Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection

tested and approved under appropriate government standards such as NIOSH (US) or EN

166(EU).

Skin protection :

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique

(without touching glove's outer surface) to avoid skin contact with this product. Dispose of

contaminated gloves after use in accordance with applicable laws and good laboratory practices.

Wash and dry hands.

The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and

the standard EN 374 derived from it.

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique

(without touching glove's outer surface) to avoid skin contact with this product. Dispose of

contaminated gloves after use in accordance with applicable laws and good laboratory practices.

Wash and dry hands.

The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and

the standard EN 374 derived from it.

Body Protection :

Complete suit protecting against chemicals, Flame retardant antistatic protective clothing., The

type of protective equipment must be selected according to the concentration and amount of the

dangerous substance at the specific workplace.

Respiratory protection :

Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator

with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup

to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air

respirator. Use respirators and components tested and approved under appropriate government

standards such as NIOSH (US) or CEN (EU).

Control of environmental exposure :

Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 18(4) for transported isolated intermediate. Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management system is available at each site. Written confirmation of application of Strictly Controlled Conditions has been received from every Downstream user of the intermediate.

Stability and reactivity

Chemical stability : Stable under recommended storage conditions.

Conditions to avoid : Heat, flames and sparks.

Incompatible materials : Strong acids

Hazardous decomposition products formed under fire conditions :  Carbon oxides, Sulphur oxides,Hydrogen fluoride, silicon oxides

Disposal considerations

Product :

Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting

as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal

company.

Contaminated packaging : Dispose of as unused product.