Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
no

Test material

1
Chemical structure
Reference substance name:
Ginger, ext.
EC Number:
283-634-2
EC Name:
Ginger, ext.
Cas Number:
84696-15-1
Molecular formula:
N/A
IUPAC Name:
Essential oil extract of Zingiber officinalis (Zingiberaceae) root GINGER ESSENTIAL OIL Ginger Oil Ginger Oleoresin Ginger, ext Ginger, ext. Ginger, Extrakt HE Zingiber officinalis INCI name: Zingiber Officinale (Ginger) Root Extract OILS, GINGER Reaction mass of camphene and pin-2(3)-ene and 7-methyl-3-methyleneocta-1,6-diene and pin-2(10)-ene and cineole and [S-(R*,S*)]-5-(1,5-dimethylhexen-4-yl)-2-methyl-1,3-cyclohexa-1,3-diene and (R)-p-mentha-1,8-diene Zingiber officinalis, Zingiberaceae.

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
ca. 245 °C
Atm. press.:
ca. 101.3 kPa

Any other information on results incl. tables

    

Injection

No.

 

Injection volume

of the sample

 100 μL  150 μL  200 μL  
 Whether any cool-flame occurred  No No   No  
1            Test temperature (℃)  254  248  248  
 

Whether any hot-flame occurred

in 10 min

 Yes Yes   Yes  
 Delay time (s)  30  41  43  
 Hot-flame temperature (℃)  260  252  254  
          2  Test temperature (℃)  251  245  245  
 

Whether any hot-flame occurred

in 10 min

 Yes  No  Yes  
 Delay time (s)  40  48  
 Hot-flame temperature (℃)  257  253  
3            Test temperature (℃)  248    242  
 

Whether any hot-flame occurred

in 10 min

No   /  No  
 Delay time (s)  /  /  /  
 Hot-flame temperature (℃)  /    /  

According to the test data, the auto-ignition temperature of the sample can be confirmed to

be 245℃ (101.3 kPa).

Applicant's summary and conclusion

Conclusions:
According to the test data, the auto-ignition temperature of the sample can be confirmed to be 245℃ (101.3 kPa).