Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 266-605-9 | CAS number: 67219-55-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Vapour pressure
Administrative data
Link to relevant study record(s)
- Endpoint:
- vapour pressure
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2018-01-08 to 2018-04-06
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 104 (Vapour Pressure Curve)
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.4 (Vapour Pressure)
- GLP compliance:
- no
- Type of method:
- effusion method: vapour pressure balance
- Temp.:
- 20 °C
- Vapour pressure:
- < 0 Pa
- Temp.:
- 25 °C
- Vapour pressure:
- < 0 Pa
- Temp.:
- 50 °C
- Vapour pressure:
- < 0 Pa
- Conclusions:
- The vapour pressure of the test item was determined according to the OECD guidline 104 by effusion method using a vapour pressure balance. The measured values were in the range of the detection limit and therefore the vapour pressures for 20 °C, 25 °C and 50 °C were estimated using the Antoine equation. Based on the measured vapour pressure at 120 °C, the following upper limit vapour pressures for the test item were calculated:
20 °C: < 4.6 x 10E-8 Pa;
25 °C: < 8.9 x 10E-8 Pa;
50 °C: < 1.8 x 10E-6 Pa. - Executive summary:
The vapour pressure of the test item was determined according to the OECD guidline 104 by effusion method using a vapour pressure balance. The measured values were in the range of the detection limit and therefore the vapour pressures for 20 °C, 25 °C and 50 °C were estimated using the Antoine equation. Based on the measured vapour pressure at 120 °C, the following upper limit vapour pressures for the test item were calculated:
20 °C: < 4.6 x 10E-8 Pa;
25 °C: < 8.9 x 10E-8 Pa;
50 °C: < 1.8 x 10E-6 Pa.
Reference
The vapour pressure was measured in the temperature range of 70 °C to 120 °C. The temperature range was chosen due to preliminary information about the test item. A vapour pressure measurement at ambient temperature was not possible due to the low vapour pressure of the test item. The measured vapour pressures at the corresponding temperatures are listed in the Table 1. The amount of test item was determined before (0.4830 g) and after (0.4751 g) the vapour pressure measurement. After the measurement a mass loss of approx. 2% (w/w) was observed.
Table 1: Measured vapour pressures and corresponding temperatures
Temperature / °C |
Vapour pressure / hPa |
70 |
1.7 x 10E-5 |
80 |
1.7 x 10E-5 |
90 |
2.6 x 10E-5 |
100 |
3.0 x 10E-5 |
110 |
7.9 x 10E-6 |
120 |
5.2 x 10E-6 |
The test item showed an unsusual vapor pressure behaviour during the measurement. The data points measured between 70 °C and 100 °C showed a typical deviation most likely caused by volatile impurities at the beginning of the measurement. All other values were below the detection limit (1 x 10E-5 hPa). The unusual behaviour did not influence the final results.
The values for 20 °C, 25 °C and 50 °C were estimated using the Antoine equation. The detection limit at the highest measurement point (120 °C) was used for the calculation.
Description of key information
The vapour pressure of the test item was determined according to the OECD guidline 104 by effusion method using a vapour pressure balance. The measured values were in the range of the detection limit and therefore the vapour pressures for 20 °C, 25 °C and 50 °C were estimated using the Antoine equation. Based on the measured vapour pressure at 120 °C, the following upper limit vapour pressures for the test item were calculated:
20 °C: < 4.6 x 10E-8 Pa;
25 °C: < 8.9 x 10E-8 Pa;
50 °C: < 1.8 x 10E-6 Pa.
Key value for chemical safety assessment
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.