Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 243-325-5 | CAS number: 19800-42-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2016-10-27 to 2016-10-28
- Reliability:
- 1 (reliable without restriction)
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- no
- GLP compliance:
- yes
- Analytical monitoring:
- no
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: 1000 mg/L was weighed out directly in Erlenmeyer flasks and stirred overnight.
- Eluate: Synthetic waste water acc. to OECD 209
- Differential loadings: 1000 mg/L
- Controls: Test medium without test or reference item. Triplicates at the beginning of the test + triplicates at the end of the test
-Reference item: three concentrations within the concentration range 58 - 180 mg/L and a dilution factor of 1.8., Triplicates - Test organisms (species):
- activated sludge
- Details on inoculum:
- - Preparation of inoculum for exposure: Non-adapted activated sludge from the sewage plant at Hildesheim (Municipal sewage treatment plant of 31137 Hildesheim, Germany)
- Receipt: 2016-10-27
- Pretreatment: The sludge was washed twice with chlorine free tap water and adjusted to a dry sludge concentration of 3.0 g/L ± 10 %. The sludge was used within 24 h after sampling.
- Dry sludge concentration: 2.92 g/L, corresponding to 1.46 g/L in the test vessel - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- yes
- Total exposure duration:
- 3 h
- Hardness:
- Not determined
- Test temperature:
- 20.8 °C
- pH:
- pH-value of the activated sludge 7.36
pH-value of the synthetic waste water 7.33 - Salinity:
- Not determined
- Details on test conditions:
- TEST SYSTEM
- Test vessel: 3
- 1000 mL Erlenmeyer flask, DIN 12380
- Aeration: Shaking aeration, to keep the dissolved oxygen concentration above 60 - 70 % saturation and to maintain the sludge flakes in suspension.
- Pretreatment: Stirring overnight
- No. of vessels per concentration (replicates): 3
- No. of vessels per control (replicates): 6 (Triplicates at the beginning of the test + triplicates at the end of the test.)
-No. of vessels per reference item (replicates): 9 (three concentrations within the range 58 - 180 mg/L and a dilution factor 1.8,at the end of the test)
- Composition of test medium:
Test concentration [mg/L] 1000
Test Item [mg] 500
Synthetic waste water [mL] 16
Demineralised water [mL] Filled up to 250 mL
Inoculum [mL] 250
Dilution Table for the Reference Item
Reference item concentration [mg/L] 58 100 180
Stock solution [µL]* 96.7 166.7 300
Synthetic waste water [mL] 16
Demineralised water [mL] Filled up to 250 mL
Inoculum [mL] 250
* Stock solution with 300g/L
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
After 3 h incubation, the oxygen concentration of each control, reference item and test item replicate was determined by means of oximeter immediately after transferring the solution to the measuring cell and the oxygen depletion was recorded for at least 3 minutes on a flat bed recorder.
TEST CONCENTRATIONS
Inhibition of Respiration (Preliminary Tests)
Inhibitions in the Preliminary Tests
A preliminary test (non-GLP) was carried out with the following test item concentrations of Disperse Orange 29:
1000 mg/L with two replicates. The pH was not adjusted.
Inhibitions in the Preliminary Tests
Nominal Test Item Concentration
[mg/L] pH
(test item in medium) Inhibition
[%]
1st preliminary test - without pH adjustment, direct aeration
1000 7.62 1
- -1
Based on the results of the preliminary test it can be concluded that the heterotrophic respiration as well as the nitrification are not inhibited. Therefore, the definitive study was carried out with the concentration of 1000 mg/L in 3 replicates (limit test to determine the NOEC). The concentration was weighed out directly in the Erlenmeyer flasks.
Triplicates of the control without test item were included at the beginning and at the end of the test.
A fresh sample of activated sludge taken from the sewage plant Hildesheim was used for the test procedure. It was washed twice and adjusted with chlorine free tap water if necessary to a dry sludge concentration of 3.0 g/L ± 10 %.
The reference item was tested with three concentrations within the concentration range 58 - 180 mg/L and a dilution factor of 1.8. - Reference substance (positive control):
- yes
- Remarks:
- Copper (II) sulphate pentahydrate p.a.
- Key result
- Duration:
- 3 h
- Dose descriptor:
- NOEC
- Effect conc.:
- >= 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Key result
- Duration:
- 3 h
- Dose descriptor:
- NOEC
- Effect conc.:
- >= 948 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- act. ingr.
- Basis for effect:
- inhibition of total respiration
- Results with reference substance (positive control):
- - Results with reference substance valid? Yes
- Reported statistics and error estimates:
- The NOEC was determined by calculation of statistical significance of the inhibition of respiration in comparison to the control. One Way Analysis of Variance (ANOVA) was used for NOEC calculation. When running a One Way Analysis of Variance a Normality test and an Equal Variance test were done first. P-value for both tests was 0.05. The P-value (acceptable probability of incorrectly concluding that there is a difference) isP=0.05.
The EC-value of the reference item was calculated by linear regression using software GraphPad Prism. Calculation of the confidence intervals for the EC50-value was carried out using standard procedures. The coefficient of variation of the oxygen uptake rates of the control replicates was calculated with standard methods using Excel. - Validity criteria fulfilled:
- yes
- Conclusions:
- Under the study conditions, the nominal 3 h NOEC of the test substance was ≥1000 mg/L (equivalent to ≥948 mg a.i./L).
- Executive summary:
A respiration inhibition test with activated sludge was conducted with the test substance (in the form of a dark brown solid of 94.8% purity) according to OECD Guideline 209. The test system was activated sludge of the municipal treatment plant of 31137 Hildesheim, Germany. The study was carried out under static conditions at a single limit concentration of 1000 mg/L for a duration of 3 h. The respiration rates of the control, reference and test substance replicates were measured after a contact time of three hours, and the inhibitory effects of the test and reference item were determined in comparison to the control respiration rates. The mean inhibition of respiration for the test substance replicates was 1%. No nitrification inhibition was observed at 1000 mg/L in the preliminary test and this endpoint was therefore not evaluated in the definitive test. In order to check the activity of the test system and the test conditions a reference test was carried out with copper (II) sulphate pentahydrate as reference item and the reference toxicity was determined. The EC50 value for the reference item was 110 mg/L. The validity criteria of the test guideline were fulfilled. Under the study conditions, the nominal 3 h NOEC of the test substance was ≥1000 mg/L (equivalent to ≥948 mg a.i./L) (Maischak, 2016).
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Study period:
- 1989
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study with acceptable restrictions
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- not specified
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
- Deviations:
- not specified
- GLP compliance:
- no
- Analytical monitoring:
- no
- Vehicle:
- no
- Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Laboratory culture:
- Name and location of sewage treatment plant where inoculum was collected: BS wastewater treament plant Sindlingen, Germany
- Initial biomass concentration: 2 g/L - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Test temperature:
- 22.1 - 23.8
- pH:
- 6.9-7.1
- Nominal and measured concentrations:
- Nominal: 0, 250, 500 and 1000 mg/L, equivalent to 0, 109, 219 and 437 mg a.i./L
- Reference substance (positive control):
- yes
- Remarks:
- 3,5-Dichlorophenol
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC10
- Effect conc.:
- 793.7 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC10
- Effect conc.:
- 346.8 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- act. ingr.
- Basis for effect:
- inhibition of total respiration
- Details on results:
- The EC10 was evaluated using the function "Y = ae EXP bx". Evaluation using exponential regression.
- Results with reference substance (positive control):
- Not reported.
- Validity criteria fulfilled:
- yes
- Conclusions:
- Under the study conditions, the nominal 3 h EC10was 793.7 mg/L, i.e. 346.8 mg a.i./L.
- Executive summary:
A study was conducted to determine the toxicity of the test substance (in the form of a water soluble dispersion of 43.7% purity) to wastewater sludge bacteria according to OECD Guideline 209 and EU Method C.11. Sludge at the equivalent of 2 g dry mass/L was exposed to nominal concentrations of 0, 250, 500 and 1000 mg/L, equivalent to 0, 109, 219 and 437 mg a.i./L for 3 h. The positive reference 3,5 -dichlorophenol was run in parallel at 5 and 30 ppm. Temperature, pH and oxygen inhibition were recorded at test end. Under the study conditions, the nominal 3 h EC10 was 793.7 mg/L, i.e. 346.8 mg a.i./L (Voelskow, 1989).
Referenceopen allclose all
From the oxygen depletion the oxygen uptake rates were calculated in mg O2/L×h, additionally the specific respiration rates based on the dry sludge concentration were calculated in mg O2/g×h.
The inhibition of the oxygen uptake rates of the test and reference item concentrations in % was calculated in comparison with the oxygen uptake rates of the control.
Oxygen Uptake Rates, Specific Respiration Rates and Inhibition of the Respiration of the Control and Test Item and Reference Item Concentrations
Test and Reference Item Concentration |
Repl. |
Oxygen Uptake Rate |
Inhibition |
Mean Inhibition |
Control |
1 |
31.2 |
- |
- |
2 |
31.6 |
|||
3 |
31.6 |
|||
4 |
28.8 |
|||
5 |
30.0 |
|||
6 |
30.8 |
|||
Test item |
1 |
29.2 |
5 |
1 |
2 |
32.0 |
-4 |
||
3 |
30.4 |
1 |
||
Reference item |
1 |
24.0 |
22 |
23 |
2 |
22.8 |
26 |
||
3 |
24.0 |
22 |
||
100 |
1 |
18.0 |
41 |
43 |
2 |
17.6 |
43 |
||
3 |
17.2 |
44 |
||
180 |
1 |
8.0 |
74 |
74 |
2 |
8.0 |
74 |
||
3 |
8.4 |
73 |
Repl. = Replicate
Coefficient of variation of oxygen uptake rates of the control: 3.6%
Suspended solids in the test vessel: 1.46 g/L
Specific Respiration Rates of the Control Replicates
|
|
Repl. |
Specific Respiration Rate Rs |
|
Control |
1 |
21.4 |
2 |
21.6 |
||
3 |
21.6 |
||
4 |
19.7 |
||
5 |
20.5 |
||
6 |
21.1 |
||
Mean value |
21.0 |
Repl. = Replicate
Suspended solids in the test vessel: 1.46 g/L
Description of key information
Value used for CSA:
EC10, LC10 or NOEC for microorganisms: ≥948 mg a.i./L
Key value for chemical safety assessment
Additional information
A respiration inhibition test with activated sludge was conducted with the test substance (in the form of a dark brown solid of 94.8% purity) according to OECD Guideline 209. The test system was activated sludge of the municipal treatment plant of 31137 Hildesheim, Germany. The study was carried out under static conditions at a single limit concentration of 1000 mg/L for a duration of 3 h. The respiration rates of the control, reference and test substance replicates were measured after a contact time of three hours, and the inhibitory effects of the test and reference item were determined in comparison to the control respiration rates. The mean inhibition of respiration for the test substance replicates was 1%. No nitrification inhibition was observed at 1000 mg/L in the preliminary test and this endpoint was therefore not evaluated in the definitive test. In order to check the activity of the test system and the test conditions a reference test was carried out with copper (II) sulphate pentahydrate as reference item and the reference toxicity was determined. The EC50 value for the reference item was 110 mg/L. The validity criteria of the test guideline were fulfilled. Under the study conditions, the nominal 3 h NOEC of the test substance was ≥1000 mg/L (equivalent to ≥948 mg a.i./L) (Maischak, 2016).
A study was conducted to determine the toxicity of the test substance (in the form of a water soluble dispersion of 43.7% purity) to wastewater sludge bacteria according to OECD Guideline 209 and EU Method C.11. Sludge at the equivalent of 2 g dry mass/L was exposed to nominal concentrations of 0, 250, 500 and 1000 mg/L, equivalent to 0, 109, 219 and 437 mg a.i./L for 3 h. The positive reference 3,5 -dichlorophenol was run in parallel at 5 and 30 ppm. Temperature, pH and oxygen inhibition were recorded at test end. Under the study conditions, the nominal 3 h EC10 was 793.7 mg/L, i.e. 346.8 mg a.i./L (Voelskow, 1989).
For risk assessment purposes, the results from the more recent study using purer test substance (Maischak, 2016) are taken into account.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.