Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 02 May 2016 to 24 June 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Cross-reference
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7550 (Partition Coefficient, n-octanol / H2O, Shake Flask Method)
Version / remarks:
1996
Deviations:
no
GLP compliance:
yes
Type of method:
flask method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Ethyl 1,3-dihydro-1,3-dioxo-2H-isoindole-2-carboxylate
EC Number:
245-048-5
EC Name:
Ethyl 1,3-dihydro-1,3-dioxo-2H-isoindole-2-carboxylate
Cas Number:
22509-74-6
Molecular formula:
C11H9NO4
IUPAC Name:
ethyl 1,3-dioxo-2,3-dihydro-1H-isoindole-2-carboxylate
Test material form:
solid
Details on test material:
- Appearance: white solid
- Storage conditions of test material: in refrigerator (2-8°C)

Study design

Analytical method:
other: ultra performance liquid chromatography (UPLC)

Results and discussion

Partition coefficient
Key result
Type:
log Pow
Partition coefficient:
1.1
Temp.:
20 °C
pH:
>= 6.6 - <= 6.9
Details on results:
- The analysed concentration of the stock solution was 0.0304 g/L; nominal quantity of the substance in each test sample was 0.0608 mg.
- The recoveries were determined to be in the range 88% - 98%.
- No test substance was detected in the pretreated phases from the blank test sample.
- The log Pow values were within the criterion range of ± 0.3 log units.


Any other information on results incl. tables

Table: Shake-flask results

  

Ratio
n-octanol : water
[v:v]

Analysed concentration

Pow

log Pow

pH

n-octanol
[g/L]

water (1)
[g/L]

individual

mean

1:1

0.00882

0.00065

14

15 

1.1

6.6

 

0.00911

0.00058

16

 

1.2

6.7

 

 

 

 

 

 

 

1:2

0.0129

0.00081

16 

15 

1.2

6.8

 

0.0117

0.00088

13 

 

1.1

6.8

 

 

 

 

 

 

 

2:1

0.00718

0.00060

12 

13 

1.1

6.9

 

0.00712

0.00054

13

 

1.1

6.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mean

14

 

1.1

 

Standard deviation

1.6

 

 

 

(1) Calculated by extrapolation of the calibration curve.

Applicant's summary and conclusion

Conclusions:
The log Pow of the substance Carbaethoxyphthalimid at neutral pH and 20°C was determined to be 1.1.
Executive summary:

The partition coefficient was determined using the shake-flask method in a GLP study according to EC A.8, OECD 107 and OPPTS 830.7550.

Quantitative analysis was performed by UPLC. Recoveries were in the range of 88 -98%. The log Pow of the substance Carbaethoxyphthalimid at neutral pH and 20°C was determined to be 1.1.