Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2013-03-07 to 2013-05-07
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 013
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Series on Testing and Assessment No. 29 (23-Jul-2001): Guidance document on transformation/dissolution of metals and metal compounds in aqueous media
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- signed, 2011-02-07
- Type of method:
- flask method
- Remarks:
- analysis by ICP-MS
Test material
- Test material form:
- other: solid
- Details on test material:
- - Name of test material (as cited in study report): optical glass
- Chemical name: Inorganic glass
- Physical state: colourless, transparent solid, odourless
- Storage condition of test material: Store in dry environment. Avoid high humidity.
Constituent 1
Results and discussion
Water solubilityopen allclose all
- Water solubility:
- 60.1 µg/L
- Temp.:
- 21.1 °C
- pH:
- >= 4.6 - <= 5.8
- Remarks on result:
- other: dissolved lead, SD: 17.2 µg/L, at 1 mg/L loading, after 28 days, with blank subtraction
- Water solubility:
- 18.7 µg/L
- Temp.:
- 21.1 °C
- pH:
- >= 5.7 - <= 6.1
- Remarks on result:
- other: dissolved lead, SD: 2.08 µg/L, at 1 mg/L loading, after 7 days, with blank subtraction
- Water solubility:
- 46.3 µg/L
- Temp.:
- 21.1 °C
- pH:
- >= 6.4 - <= 6.6
- Remarks on result:
- other: dissolved lead, SD: 5.83 µg/L, at 1 mg/L loading, after 28 days, with blank subtraction
- Water solubility:
- 17.7 µg/L
- Temp.:
- 21.1 °C
- pH:
- >= 6.7 - <= 6.9
- Remarks on result:
- other: dissolved lead, SD: 1.36 µg/L, at 1 mg/L loading, after 7 days, with blank subtraction
- Water solubility:
- 37.8 µg/L
- Temp.:
- 21.1 °C
- pH:
- >= 7.4 - <= 7.5
- Remarks on result:
- other: dissolved lead, SD: 3.64 µg/L, at 1 mg/L loading, after 28 days, with blank subtraction
- Water solubility:
- 17 µg/L
- Temp.:
- 21.1 °C
- pH:
- >= 7.5 - <= 7.6
- Remarks on result:
- other: dissolved lead, SD: 1.99 µg/L, at 1 mg/L loading, after 28 days, with blank subtraction
- Details on results:
- Temperature
The temperature of the thermostatically controlled room was recorded with a data logger. The mean temperatures were 21.1 ± 0.4 °C. Therefore the mean temperature is in agreement with the OECD guidance document 29.
Solution pH values and oxygen levels
According to the guidance, the solution pH can be expected to remain constant (± 0.2 units) during most tests.
The solution pH remained relatively constant for the pH 6 treatment till sampling day 7 (168h). After day 7 the pH in vessel 3 (sample and blank vessels) decreases till day 28. In vessel 2 (sample and blank vessels) after day 14 (336h) the pH decreases till day 28. In test item vessels pH was in the range of 4.6 – 6.2 and in method blank vessels pH was in the range of 4.3 – 6.2. Therefore, an effect of the test substance can be excluded.
Oxygen levels in all test vessels pH 6 were in the range recommended by the OECD Test Guidance 29 during the test: above 70 % of oxygen saturation at 8.5 mg/L (70 % of 8.5 mg/L = 6 mg/L).
The solution pH remained relatively constant for the pH 7 treatment at the pH which was measured at the sampling time 2h. After day 4 the pH in vessel 1 and 2 (sample vessels) increases till day 14 and afterwards the pH decreases till day 28. In test item vessels pH was in the range of 6.4 – 6.9 and in method blank vessels pH was in the range of 6.1 – 6.9. Therefore, an effect of the test substance can be excluded
Oxygen levels in all test vessels pH 7 were in the range recommended by the OECD Test Guidance 29 during the test: above 70 % of oxygen saturation at 8.5 mg/L (70 % of 8.5 mg/L = 6 mg/L).
The solution pH remained relatively constant for the pH 8 treatment at the pH which was measured at the sampling time 2h. In the test item vessels pH was in the range of 7.3 – 7.6 and in method blank vessels pH was in the range of 7.3 – 7.8.
Oxygen levels in all test vessels pH 8 were in the range recommended by the OECD Test Guidance 29 during the test: above 70 % of oxygen saturation at 8.5 mg/L (70 % of 8.5 mg/L = 6 mg/L).
The discrepancy in the pH for the setting for pH 6 could result on the usage of polycarbonate vessels instead of glass vessels. The decrease of the pH in test vessels and in method blank vessels can be explained by a possible leaching effect of the polycarbonate vessels. The vessels were washed prior to the test with HNO3 and H+ ions could be absorbed onto the polycarbonate walls and released after a period of time. This could influence the pH of the media and in the case of the pH 6 test just a less amount of H+ ions could have a greater effect to the pH than in the pH 7 and 8 test.
Mass balance calculation
Samples were taken from vessels at least 12 hours after adding aqua regia to dissolve the residues. Dissolved lead concentration was measured by ICP-MS and the mass balance was calculated considering the replacement of sampling solution after each sampling by adding blank test media (120 mL after 24h and 40 mL after each subsequent sampling). The filters used for sampling were extensively rinsed with an exact amount of aqua regia and the lead concentration in the filtrate was determined and considered in the mass balance calculation.
The nominal amount of lead was calculated by:
Added test item (mg) * 35.65[§] (percentage of Pb in test item).
[§] according to the SDS/MSDS 38.4% Pb as leadoxides (considered as PbO) in the raw material for production of glass=> 92.8321 % lead in PbO=> (38.4 % * 92.8321 %)/100 % = 35.65% Pb in test item
Recovery of lead in one mass balance sample (vessel and filter/syringes) for each pH.
Vessel Measured Added test Volume Calculated amount Pb in filters Amount of Pb Lead recovery in
Pb conc item of lead in in final column relation to Zn in
final volume plus Pb in filter added test item
[µg/L] [mg] [L] [mg] [mg] [mg] [%]
1 pH 6 301 1.253 1.743 0.524 0.003 0.527 118
1 pH 7 316 1.115 1.605 0.508 0.003 0.511 128
3 pH 8 287 1.325 1.840 0.529 0.002 0.531 112
It has to be considered that for the optical glass only a product information is given in which lead concentration in the raw material as leadoxides (considered as PbO) is given. Possible impurities in the other raw materials which were used for production are not specified in detail. Furthermore no lead concentration in the final product is defined. Therefore the recovery of lead in the mass balance differ and result in a higher recovery as calculated by the loading of the test item into the test vessels.
Any other information on results incl. tables
Fortification of test samples.
sample |
measured concentration [µg/L] |
calculated level after addition [µg/L] |
recovery |
Vessel 1 sample a 14d (336h) pH6 |
28.2 |
42.5 |
41.1 / 96.5 |
Vessel 1 sample b 14d (336h) pH6 |
27.7 |
42.1 |
41.7 / 98.9 |
Vessel 2 sample a 14d (336h) pH7 |
31.7 |
45.3 |
44.6 / 98.3 |
Vessel 2 sample b 14d (336h) pH7 |
31.7 |
45.3 |
42.8 / 94.5 |
Vessel 3 sample a 14d (336h) pH8 |
22.6 |
38.0 |
36.8 / 96.7 |
Vessel 3 sample b 14d (336h) pH8 |
21.1 |
36.9 |
36.4 / 98.7 |
The certified reference materials TM-15.2 (certified with 11.6 µg/L lead, diluted to 1.16 µg/L dilution factor 10) and TMDA70 (certified with 444 µg/L lead, diluted to 44.4 µg/L dilution factor 10) as well as the recalibration standard (5 µg Pb/L and 1 µg Pb/L) were analyzed as quality assurance samples along with the mass balance samples (vessels and filters). To meet quality assurance requirements recovery needs to be in the range of ± 15 % of the respective certified value.
For the measurement series of the mass balance, the mean accuracy and precision were 103 ± 4.4 % (n = 7) for TM-15.2 (dilution factor 10) and 102 ± 4.1 % (n = 5) for TMDA70 (dilution factor 10). The average recovery for the recalibration standard 5 µg Pb/L was 95.7 ± 0.7 % (n = 3) and for 1 µg Pb/L 101 ± 0.9 % (n = 2).
As further quality assurance measurement, routine analyses of method blank samples were performed. Elevated concentrations of Pb in method blanks origin from applied chemicals for preparation of different media. Although all used chemicals are at least of pro Analysis quality, low metal amounts cannot be excluded.
Lead concentration in method blanks.
Media |
|
pH 6 |
Method blanks mainly above LOD/LOQ except for method blanks 2h (three blanks <LOD, two <LOQ, one >LOQ --> 0.04 µg/L --> 7.90 fold lower than concentration in samples) and 6h (five blanks <LOQ, one >LOQ --> 0.09 µg/L --> 11.0 fold lower than concentration in samples); method blanks of further sampling points above LOQ but at least 177 -494 fold lower than concentration in samples |
pH 7 |
Method blanks mainly above LOD/LOQ except for method blanks 2h (three blanks <LOQ, three >LOQ --> 0.02 µg/L --> 16.5 fold lower than concentration in samples) and 6h (four blanks <LOQ, two >LOQ --> 0.03 – 0.04 µg/L --> 25.7 fold lower than concentration in samples); method blanks of further sampling points above LOQ but at least 141 - 601 fold lower than concentration in samples |
pH 8 |
Method blanks mainly above LOD/LOQ except for method blanks 6h (two blanks <LOQ, four >LOQ --> 0.03 – 0.04 µg/L --> 27.2 fold lower than concentration in samples); method blanks of further sampling points above LOQ but at least 11.1 - 441 fold lower than concentration in samples |
Method validation summary.
validation parameter |
results |
Comment |
Selectivity |
similar data with two different gas modes |
No interference observed |
Linearity |
applied calibration functions were linear |
correlation coefficient at least 0.9953 |
Limit of detection |
0.001 – 0.01 µg/L |
|
Limit of quantification |
0.004 – 0.03 µg/L |
|
Method blanks |
Summary seeTable11 |
Elevated concentrations of Pb in method blanks origin from the applied chemicals for preparation of different media |
Accuracy measurement test samples and method blanks |
Mean recovery for CRM TM15.2 (dilution factor 5): |
Low concentration range (11.6 µg Pb/L – diluted 2.32 µg Pb/L) |
Accuracy measurement test samples and method blanks |
Mean recovery for CRM TMDA70 (dilution factor 10): |
High concentration range (444 µg Pb/L – diluted 44.4 µg Pb/L) |
Accuracy mass balance |
Mean recovery for CRM TM15.2 (dilution factor 10): |
Low concentration range (11.6 µg Pb/L – diluted 1.16 µg Pb/L) |
Accuracy mass balance |
Mean recovery for CRM TMDA70 (dilution factor 10): |
High concentration range (444 µg Pb/L – diluted 44.4 µg Pb/L) |
Trueness measurement test samples and method blanks |
mean recovery for recalibration standard: |
Mid concentration range (10 µg/L) |
Trueness mass balance |
mean recovery for recalibration standard: |
Mid low concentration range |
Trueness mass balance |
mean recovery for recalibration standard: |
Low concentration range |
Trueness measurement test samples and method blanks |
Fortification of samples: |
|
Reproducibility measurement test samples and method blanks |
Mean recovery for CRM TM15.2 (dilution factor 5): |
Low concentration range (11.6 µg Pb/L – diluted 2.32 µg Pb/L) |
Reproducibility measurement test samples and method blanks |
Mean recovery for CRM TMDA70 (dilution factor 10): |
High concentration range (444 µg Pb/L – diluted 44.4 µg Pb/L) |
Reproducibility mass balance |
Mean recovery for CRM TM15.2 (dilution factor 10): |
Low concentration range (11.6 µg Pb/L – diluted 1.16 µg Pb/L) |
Reproducibility mass balance |
Mean recovery for CRM TMDA70 (dilution factor 10): |
High concentration range (444 µg Pb/L – diluted 44.4 µg Pb/L) |
Results
Under the described conditions of this test with inorganic glass (KZFSN5 optical glass), the following dissolved concentrations were measured at the respective loading, exposure and solution pH:
1 mg/L loading after 28 days pH 6 without blank subtraction:
- Lead: 60.5 ± 17.2 µg/L
1 mg/L loading after 28 days pH6 with blank subtraction:
- Lead: 60.1 ± 17.2 µg/L
1 mg/L loading after 28 days pH 7 without blank subtraction:
- Lead: 46.4 ± 5.83 µg/L
1 mg/L loading after 28 days pH 7 with blank subtraction:
- Lead: 46.3 ± 5.83 µg/L
1 mg/L loading after 28 days pH 8 without blank subtraction:
- Lead: 37.9 ± 3.64 µg/L
1 mg/L loading after 28 days pH 8 with blank subtraction:
- Lead: 37.8 ± 3.64 µg/L
The OECD Series 29 requires a limit of 20 % and 10 % for the between-vessel and within vessel variation, respectively.
Loading 1 mg/L pH 6 without blank subtraction:
Lead: The observed variations within the test flasks were in compliance with the guidance except for the within-vessel variations of vessel 1 (20.0 %) after 2 h and vessel 2 (11.8 %) after 504 h. The observed variations between the test flasks over the experimental period were in the range of 11.1 – 28.5 %.
Loading 1 mg/L pH 6 with blank subtraction:
Lead: The observed variations within the test flasks were in compliance with the guidance except for the within-vessel variations of vessel 1 and 2 (23.3 and 10.9 %) after 2 h , vessel 2 (10.1 %) after 6h and vessel 2 (11.9 %) after 504 h. The observed variations between the test flasks over the experimental period were in the range of 11.1 – 28.7 %.
Loading 1 mg/L pH 7 without blank subtraction:
Lead: The observed variations within the test flasks were in compliance with the guidance except for the within-vessel variations of vessel 1 (19.5 %) after 672 h. The observed variations between the test flasks over the experimental period were in the range of 5.81 – 12.6 %.
Loading 1 mg/L pH 7 with blank subtraction:
Lead: The observed variations within the test flasks were in compliance with the guidance except for the within-vessel variations of vessel 1 (19.6 %) after 672 h. The observed variations between the test flasks over the experimental period were in the range of 5.81 – 12.6 %.
Loading 1 mg/L pH 8 without blank subtraction:
Lead: The observed variations within the test flasks were in compliance with the guidance except for the within-vessel variations of vessel 2 (10.5 %) after 24 h. The observed variations between the test flasks over the experimental period were in the range of 3.82 – 15.3 %.
Loading 1 mg/L pH 8 with blank subtraction:
Lead: The observed variations within the test flasks were in compliance with the guidance except for the within-vessel variations of vessel 2 (10.6 %) after 24 h. The observed variations between the test flasks over the experimental period were in the range of 3.97 – 15.4 %.
According to the guidance, it is reasonable to anticipate that for a constant loading of a substance, tested in a narrow particle size (e.g., 37 - 44 μm) and total surface area range, the within-vessel variation in transformation data should be less than 10 % and the between-vessel variation should be less than 20 %. The observed increased between-vessel variations may be due to the wider particle size distribution of the test item. The particle size distribution of each loading replicate may differ and thus resulting in different overall total surface areas per vessel. Since the exposed surface area is affecting the rate of transformation and dissolution of sparingly soluble metal compounds, increases in between-vessel variations may be observed in tests of materials with wider particle size distributions.
Applicant's summary and conclusion
- Conclusions:
- Interpretation of results (migrated information): slightly soluble (0.1-100 mg/L)
Under the described conditions of this test with inorganic glass (optical glass), the following dissolved concentrations were measured at the respective loading, exposure and solution pH:
1 mg/L loading after 7 days pH 6 with blank subtraction: Lead: 18.7 ± 2.08 µg/L
1 mg/L loading after 28 days pH 6 with blank subtraction: Lead: 60.1 ± 17.2 µg/L
1 mg/L loading after 7 days pH 7 with blank subtraction: Lead: 17.7 ± 1.36 µg/L
1 mg/L loading after 28 days pH 7 with blank subtraction: Lead: 46.3 ± 5.83 µg/L
1 mg/L loading after 7 days pH 8 with blank subtraction: Lead: 17.0 ± 1.99 µg/L
1 mg/L loading after 28 days pH 8 with blank subtraction: Lead: 37.8 ± 3.64 µg/L
The maximum dissolution of Pb from the test item is 6.01% (w/w).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
Although ECHA is providing a lot of online material in your language, part of this page is only in English. More about ECHA’s multilingual practice.
Welcome to the ECHA website. This site is not fully supported in Internet Explorer 7 (and earlier versions). Please upgrade your Internet Explorer to a newer version.
the-echa-website-uses-cookies
find-out-more-on how-we-use-cookies