Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 7, 2011
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Solid Recovered Fuel (Municipal Solid Waste and similar wastes, processed)
EC Number:
700-869-2
Molecular formula:
Not applicable
IUPAC Name:
Solid Recovered Fuel (Municipal Solid Waste and similar wastes, processed)
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
Name: CarboNeXT
Physical state: fine powder
Colour: greyish
Storage conditions: at room temperature, protected from light

Results and discussion

In vitro

Results
Irritation parameter:
cornea opacity score
Value:
2.88
Remarks on result:
no indication of irritation

Any other information on results incl. tables

The eye irritancy potential of CarboNeXT was investigated in the bovine corneal opacity and permeability assay.


The test item was diluted with physiological saline 0.9% NaCl to gain a 20% concentration.


The following mean in vitro score was calculated: 2.88


Therefore the test item was classified as non irritant.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
According to the evalutation criteria the test item CarboNeXT is classified as non eye irritant.