Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP and appropriate guidelines
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Principles of method if other than guideline:
n/a
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
Diethyl (hydroxymethyl)phosphonate
EC Number:
221-391-6
EC Name:
Diethyl (hydroxymethyl)phosphonate
Cas Number:
3084-40-0
Molecular formula:
C5H13O4P
IUPAC Name:
diethyl (hydroxymethyl)phosphonate
Constituent 2
Reference substance name:
Diethoxyphosphoryl methanol
IUPAC Name:
Diethoxyphosphoryl methanol
Test material form:
other: "medium viscosity" liquid
Details on test material:
E06-16 (Batch No. 2206-74-2), a colotless liquid. Stored in dark at room temp. (Approximately 25oC).
The test material was stable for the duration of the study.

Results and discussion

Flash point
Flash point:
> 400 °C
Remarks on result:
other: no flash point of E06-16 could be determined up to 400 °C.

Any other information on results incl. tables

Not relevant

Applicant's summary and conclusion

Conclusions:
no flash point of E06-16 could be determined up to 400 °C.
Executive summary:

no flash point of E06-16 could be determined up to 400 °C.