Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 07 December 2017. Experimental completion date: 29 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: BAM Friction Test
Remarks on result:
negative (not further specified)
Parameter:
other: BAM Fall Hammer test
Remarks on result:
negative (not further specified)
Parameter:
other: Koenen Stell Tube Test
Remarks:
6 mm and 2 mm oriface plate
Remarks on result:
negative (not further specified)

Any other information on results incl. tables

Preliminary Tests:

For the friction test, a small amount of test item on an anvil was rubbed with a mallet on an anvil but no evidence of ignition was observed. For the shock test, a small amount of test on an anvil was hit with a mallet but no evidence of ignition was observed. For the thermal strain test, a small amount of test item on a spatula was placed in an air-rich Bunsen flame; the test item melted to an orange liquid before igniting giving an orange flame and grey

fumes. Further heating caused the flame to quickly self-extinguish leaving a black, charred solid residue.

BAM Friction Test:

Results of the BAM Friction test are shown in the following table.

Replicate

Observations

1

No flash, flames or noise from sample during test. Post-test inspection of the test item showed a slight discoloration to a dull yellow colour along the porcelain peg’s path and top of the peg.

2

As replicate 1

3

As replicate 1

4

As replicate 1

5

As replicate 1

6

As replicate 1

Result: Negative.

BAM Fall Hammer Test:

Results of the BAM Fall Hammer test are shown in the following table:

Replicate

Observations

1

No noise, flames or fumes from sample during test. Post-test inspection revealed no discoloration or degradation of sample.

2

As replicate 1

3

As replicate 1

4

As replicate 1

5

As replicate 1

6

As replicate 1

Result: Negative.

Koenen Steel Tube Test:

Results of the Koenen Steel Tube test are shown in the following tables:

Koenen Steel Tube Test - 6 mm Oriface Plate

Replicate

Time (s)

Observations

1

14

Orange flame from orifice

32

Sparks emitted from orifice

40

Test item ejected from orifice

157

Flame decreasing in size

300

Test stopped

2

12

Orange flame from orifice

21

Sparks emitted from orifice

33

Test item ejected from orifice

178

Charred test item building up on outside of tube

190

Orange flame decreasing in size

300

Test stopped

3

11

Orange flame from orifice

17

Sparks emitted from orifice

22

Test item ejected from orifice

170

Flame decreasing in size

300

Test stopped

Result: Negative

Koenen Steel Tube Test - 2 mm Oriface Plate

Replicate

Time (s)

Observations

1

14

Orange flame from orifice

21

Flame included sparks and becoming jet-like

32

Flame is a full jet

42

Test item ejected from orifice

69

Flame decreasing in size

198

Charred test item building up on outside of tube

300

Test stopped

2

12

Orange flame from orifice

20

Sparks emitted from orifice

26

Orange jet of flame from orifice

53

Test item ejected from orifice

62

Flame decreasing in size

177

Charred test item deposited on top of orifice plate

300

Test stopped, orange flame continued to burn

3

15

Orange flame from orifice

21

Sparks emitted from orifice

38

Orange jet of flame from orifice

44

Test item ejected from orifice

74

Flame decreasing in size

169

Charred test item deposited on orifice plate

300

Test stopped, orange flame continued to burn

Result: Negative

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item has been determined to not have explosive properties.
Executive summary:

The determination was carried out using a procedure designed to be compatible with Method A.14 Explosive Properties of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 830.6316 of the OCSPP Guidelines.

Negative results were obtained in BAM friciton test, BAM fall hammer test and Koenen steel tube test (6 and 2 mm oriface plates).

The test item has been determined to not have explosive properties.