Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
water solubility
Type of information:
(Q)SAR
Adequacy of study:
key study
Study period:
2 December 2018 and 3 December 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
WSKOWWIN (via EPISuite)

2. MODEL (incl. version number)
OPERA v1.5

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
Smiles: C1=CC2=C3C(=C(C=C2S(=O)(=O)[O-])S(=O)(=O)[O-])C=CC4=C(C=C(C1=C43)S(=O)(=O)[O-])S(=O)(=O)[O-].[Na+].[Na+].[Na+].[Na+]
Substance name: Tetrasodium 1,3,6,8-pyrenetetrasulfonate
CAS: 59572-10-0

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
KREATiS explanation for Klimisch 2: Final QSAR result is reliable and can reliably replace an experimental result with the OECD Guideline for Testing of Chemicals No. 105, "Water Solubility".

5. APPLICABILITY DOMAIN
This QSAR model has been designed to be used for regulatory purposes and based on the QSAR results, this report predicts the consensus endpoint value which would be expected when testing the substance under experimental conditions in a laboratory following the OECD Guideline for Testing of Chemicals No. 105, "Water Solubility".

6. ADEQUACY OF THE RESULT
Based on multiple QSAR models applied, the final Water Solubility for Tetrasodium 1,3,6,8-pyrenetetrasulfonate was predicted as 311400 mg/L.
The final QSAR result can be associated with a Klimisch score: K2
Guideline:
other: REACH Guidance on QSARs R.6
Version / remarks:
OECD (2004) Principles for the validation, for regulatory purposes, of (Quantitative) Structure Activity-Relationship Models, http://www.oecd.org/env/ehs/risk-assessment/oecdquantitativestructureactivityrelationshipsprojectqsars.htm
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
OECD (2004) Principles for the validation, for regulatory purposes, of (Quantitative) Structure Activity-Relationship Models, http://www.oecd.org/env/ehs/risk-assessment/oecdquantitativestructureactivityrelationshipsprojectqsars.htm
Specific details on test material used for the study:
C1=CC2=C3C(=C(C=C2S(=O)(=O)[O-])S(=O)(=O)[O-])C=CC4=C(C=C(C1=C43)S(=O)(=O)[O-])S(=O)(=O)[O-].[Na+].[Na+].[Na+].[Na+]
Key result
Water solubility:
311 400 mg/L
Remarks on result:
other: Temperature and pH not available as in silico method used to determine result.
Conclusions:
The final Water Solubility predicted for Tetrasodium 1,3,6,8-pyrenetetrasulfonate assigned by the study investigator: 311400 mg/L
Executive summary:

Introduction. Multiple Quantitative Structure Activity Relationship (QSAR) models was used to predict the water solubility of the test item Tetrasodium 1,3,6,8-pyrenetetrasulfonate. These QSAR models has been designed to be used for regulatory purposes and based on the QSAR results, this report predicts the consensus endpoint value which would be expected when testing the substance under experimental conditions in a laboratory following the OECD Guideline for Testing of Chemicals No. 105, "Water Solubility"

Methods. The purpose of the in silico study was to predict the Water Solubility of the test item Tetrasodium 1,3,6,8-pyrenetetrasulfonate. This prediction was performed using the following QSAR model.

WSKOWWIN (via EPISuite)

 

Results.

Based on multiple QSAR models applied, the final Water Solubility for Tetrasodium 1,3,6,8-pyrenetetrasulfonate was predicted as 311400mg/L.

The final QSAR result can be associated with a Klimisch score: K2

Endpoint:
water solubility
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Remarks:
using QSAR
Adequacy of study:
supporting study
Study period:
2 December 2018 and 3 December 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Justification for type of information:
QSAR information

1. SOFTWARE
WSKOWWIN (via EPISuite)

2. MODEL (incl. version number)
OPERA v1.5

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
Smiles: [Na+].[Na+].[Na+].OC1=C2C=CC3=C(C=C(C4=CC=C(C(=C1)S([O-])(=O)=O)C2=C34)S([O-])(=O)=O)S([O-])(=O)=O
Substance name: trisodium 8-hydroxypyrene-1,3,6-trisulfonate
CAS: 6358-69-6

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
KREATiS explanation for Klimisch 2: Final QSAR result is reliable and can reliably replace an experimental result with the OECD Guideline for Testing of Chemicals No. 105, "Water Solubility".

5. APPLICABILITY DOMAIN
This QSAR model has been designed to be used for regulatory purposes and based on the QSAR results, this report predicts the consensus endpoint value which would be expected when testing the substance under experimental conditions in a laboratory following the OECD Guideline for Testing of Chemicals No. 105, "Water Solubility".

6. ADEQUACY OF THE RESULT
Based on multiple QSAR models applied, the final Water Solubility for trisodium 8-hydroxypyrene-1,3,6-trisulfonate was predicted as 362000 mg/L.
The final QSAR result can be associated with a Klimisch score: K2

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Read across information

REPORTING FORMAT FOR THE ANALOGUE APPROACH

1. HYPOTHESIS FOR THE ANALOGUE APPROACH
STRUCTURAL SIMILARITY
Both the substances share the same carbon skeleton, which is pyrene. The query substance holds four sulfonates groups while the proposed analogue has one hydroxy group replacing a sulfonate. Both sulfonate and hydroxy groups are hydrophilic in nature. However, the hydroxy group is only ionised at high pHs (pKa of phenol is around 101) while the sulfonate group would remain ionised over the whole range of aqueous pHs. Therefore, Read-Across substance is expected to be slightly less hydrophilic and more volatile than the query substance, which is confirmed by the log KOW and vapour pressure studies.
Both the substances are expected to be stable in pure form or in water, and they are expected to be not volatile (high boiling point, low vapour pressure), highly hydrophilic (low log KOW, high water solubility) due to the presence of four strongly hydrophilic groups.

2. SOURCE AND TARGET CHEMICAL(S) (INCLUDING INFORMATION ON PURITY AND IMPURITIES)
See Test material sections of the source and target records for details.

3. ANALOGUE APPROACH JUSTIFICATION
DISCUSSION AND CONCLUSION
Therefore, both the structures are expected to have very similar physico-chemical properties. Moreover, Read-Across substance being less hydrophilic than the query substance, it will be a worst-case (or conservative) prediction, for instance when estimating the accumulation potential of the substance.
Consequently, trisodium 8-hydroxypyrene-1,3,6-trisulfonate is judged to be a good Read-Across for tetrasodium 1,3,6,8-pyrenetetrasulfonate.
Conclusion: Strong similarity between the predicted and experimental values suggest that there the selection of this QSAR model to predict the water solubility of the query and read-across substance was valid and reliable.
Guideline:
other: REACH Guidance on QSARs R.6
Version / remarks:
OECD (2004) Principles for the validation, for regulatory purposes, of (Quantitative) Structure Activity-Relationship Models, http://www.oecd.org/env/ehs/risk-assessment/oecdquantitativestructureactivityrelationshipsprojectqsars.htm
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
OECD (2004) Principles for the validation, for regulatory purposes, of (Quantitative) Structure Activity-Relationship Models, http://www.oecd.org/env/ehs/risk-assessment/oecdquantitativestructureactivityrelationshipsprojectqsars.htm
Specific details on test material used for the study:
[Na+].[Na+].[Na+].OC1=C2C=CC3=C(C=C(C4=CC=C(C(=C1)S([O-])(=O)=O)C2=C34)S([O-])(=O)=O)S([O-])(=O)=O
Key result
Water solubility:
362 000 mg/L
Remarks on result:
other: Temperature and pH not available as in silico method used to determine result.
Water solubility:
271 250 mg/L
Remarks on result:
other: Experimental data retrieved from the ECHA dossier https://echa.europa.eu/registration-dossier/-/registered-dossier/17360/4/9
Conclusions:
The final Water Solubility predicted for trisodium 8-hydroxypyrene-1,3,6-trisulfonate assigned by the study investigator: 311400 mg/L

Description of key information

Multiple Quantitative Structure Activity Relationship (QSAR) models was used to predict the water solubility of the test item Tetrasodium 1,3,6,8-pyrenetetrasulfonate.

Based on multiple QSAR models applied, the final Water Solubility for Tetrasodium 1,3,6,8-pyrenetetrasulfonate was predicted as 311400mg/L. The final QSAR result can be associated with a Klimisch score: K2

The same method was used to predict the water solubility of the analogue test item trisodium 8-hydroxypyrene-1,3,6-trisulfonate.The final water solubility predicted for trisodium 8-hydroxypyrene-1,3,6-trisulfonate assigned by the study investigator: 362000 mg/L. Klimisch score assigned by the study investigtor for the final prediction: K2

Test results published on the ECHA website provided a result of 271250 mg/L for water solubility for the analogue test item trisodium 8-hydroxypyrene-1,3,6-trisulfonate.

Comparison with the QSAR results for the analogue substance, together with the available data on the analogue substance indicate that testing using 8-hydroxypyrene-1,3,6-trisulfonate would be expected to provide a result consistent with that generated using QSAR.

Key value for chemical safety assessment

Water solubility:
311 400 mg/L

Additional information

Both the structures are expected to have very similar physico-chemical properties. Moreover, Read-Across substance being less hydrophilic than the query substance, it will be a worst-case (or conservative) prediction, for instance when estimating the accumulation potential of the substance.

Consequently, trisodium 8-hydroxypyrene-1,3,6-trisulfonate is judged to be a good Read-Across for tetrasodium 1,3,6,8-pyrenetetrasulfonate.

Conclusion: Strong similarity between the predicted and experimental values suggest that there the selection of this QSAR model to predict the water solubility of the query and read-across substance was valid and reliable.