Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 217-123-2 | CAS number: 1746-03-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flash point
Administrative data
Link to relevant study record(s)
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- from 2017-02-20 to 2017-07-31
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.9 (Flash-Point)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.6315 (Flammability)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: Method 32.4 “Test methods used for determining flash point and viscosity”
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- non-equilibrium method closed cup
- Flash point apparatus:
- Pensky-Martens apparatus
- Specific details on test material used for the study:
- Batch No.: VPS9016001
Purity: 97.3 % - Key result
- Remarks on result:
- no flash point - measurement carried out until boiling temperature
- Remarks:
- Heating was performed up to 199. °C. At this temperature, boiling was observed and the experiment was stopped.
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- No flash point was found for the test item up to the boiling temperature.
- Executive summary:
A study was conducted according to Regulation (EC) No 440/2008 method A.9, OPPTS 830.6315 and UN Test Method 32.4 to determine flash point of the test item using a non-equilibrium closed cup method. Two safety test with approx. 3 mL test item were performed. The test item's appearance didn't change. A pre-test with 70 mL test item was performed using Pensky-Martens apparatus. The test item was heated up to 199 °C. At this temperature, boiling was observed and the experiment was stopped.
No flash point could be determined up to the boiling point of the test item.
Reference
Safety test 1
The test item appearance did not changed after cooling down. The piece of brass was copper coloured.
Safety test 2
Formation of bubbles was observed at 230 °C with no signs for decomposition or polymerisation.
Pre-Test
In the pre-test, no flash point was detected. Heating was performed up to 199 °C. At this temperature, boiling was observed and the experiment was stopped. After cooling down the test item appeared yellow-green.
Description of key information
No flash point up to the boiling point was observed.
Key value for chemical safety assessment
Additional information
A study was conducted according to Regulation (EC) No 440/2008 method A.9, OPPTS 830.6315 and UN Test Method 32.4 to determine flash point of the test item using a non-equilibrium closed cup method. Two safety tests with approx. 3 mL test item were performed. The test item's appearance didn't change. A pre-test with 70 mL test item was performed using Pensky-Martens apparatus. The test item was heated up to 199 °C. At this temperature, boiling was observed and the experiment was stopped. No flash point could be determined up to the boiling point of the test item.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.