pH
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
CIPAC MT 75 (Determination of pH Values)
Deviations:
not specified
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Pyridine-2,6-dicarboxylic acid
EC Number:
207-894-3
EC Name:
Pyridine-2,6-dicarboxylic acid
Cas Number:
499-83-2
Molecular formula:
C7H5NO4
IUPAC Name:
pyridine-2,6-dicarboxylic acid
Test material form:
solid: crystalline

Reagents

Reagent:
buffer solutions

Results and discussion

pH value
Key result
pH value:
ca. 2
Temp.:
24.7
Concentration:
ca. 1 vol%

Any other information on results incl. tables

Determination of pH-Value of 1% Test Substance

The following values were recorded.

Table3.1‑a      pH-values

Parameter

Determination

1

T (°C)

Determination.

2

T (°C)

Mean and

Difference

pH (instantly)

2.01

24.7

2.02

24.8

 

pH (after1 min)

2.01

24.7

2.01

24.8

 

Mean

 

 

 

 

2.01

Difference

0.00

 

0.01

 

0.00

 

 

  Evaluation

The mean between both determinations gives the following pH-value:

pH-value (1% test substance):                                               2.01

Difference (1% test substance):                                             0.00

Validity

¨            The values of the single determinations showed no difference; therefore the demanded range of 0.10 is fulfilled.

¨            The pH of the standard buffer solution, pH = 9.180 was determined with no difference to the stated literature value

Applicant's summary and conclusion

Conclusions:
The determination was performed in duplicate.

Calibration of the pH-meter was performed using three buffer solutions of pH 4.006, 6.865, and 9.180, respectively.
In the control measurement, the pH-value of the standard buffer solution, pH 9.180 lay within the accepted range.

The pH-value of the 1% test item solution at 25.0 ± 0.3 °C was determined as 2.0.
Executive summary:

The determination was performed in duplicate.

 

Calibration of the pH-meter was performed using three buffer solutions of pH 4.006, 6.865, and 9.180, respectively.

In the control measurement, the pH-value of the standard buffer solution, pH 9.180 lay within the accepted range.

 

The pH-value of the 1% test item solution at 25.0 ± 0.3 °C was determined as 2.0