Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
oxidising gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
oxidising liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test O.1 (Test for oxidizing solids)
Deviations:
no
GLP compliance:
not specified
Key result
Sample tested:
test mixture (not specified)
Parameter:
preliminary test
Remarks on result:
mixture does not ignite and burn
Interpretation of results:
GHS criteria not met
Conclusions:
The substance has no oxidising properties.
Executive summary:

The authoritative database form the Institute for Occupational Safety and Health of the German Social Accident Insurance (GESTIS database) is regarded as reliable literature source. The GESTIS database reports the substance as substance with no oxidising properties.

Description of key information

Not an oxidising gas, liquid or solid.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Oxidising solids (reference 4.15-1)

The authoritative database form the Institute for Occupational Safety and Health of the German Social Accident Insurance (GESTIS database) is regarded as reliable literature source. The GESTIS database reports that the substance has no oxidising properties. In order to confirm this result a study was initiated before 31 March 2018 but was not completed by the CRO in due time to complete the registration dossier. The study record will be updated as soon as the results will become available.

 

Oxidising liquids (reference 4.15-2)

The test item is a solid at ambient conditions. This hazard class is only applicable for liquids. Thus, the substance was not considered for classification as oxidising liquid.

 

Oxidising gases (reference 4.15-3)

The test item is a solid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as oxidising gas.

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No 1272/2008

Based on the chemical structure and taking into account the provisions laid down in Regulation (EC) No. 1272/2008, as amended for the tenth time in Regulation (EC) No 2017/776, the substance is not considered to be classified for oxidising properties (references 4.15-1, 4.15-2 and 4.15-3).