Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 02nd, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 59, “Dry Sieve test”
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of distribution:
mass based distribution
Specific details on test material used for the study:
The test item was used in its initial form, without any pre-treatment.
Percentile:
D50
Mean:
75 - 250 µm
Remarks on result:
other: 96.38 % of particles have a size higher than 75 µm

Determination of particle size distribution

Sieve Size (µm) Weight of Test Item (g) Material Passed Through Sieve Residue (Rx) % 
dx, g Percentage ( %)
750 10.0007 9.8587 98.58 1.42
500 10.0015 9.6062 96.05 3.95
420 10.0074 7.2525 72.47 27.53
250 10.0181 7.1809 71.68 28.32
75 10.0034 0.3626 3.62 96.38
Conclusions:
D50: 75 - 250 µm
Executive summary:

The dry sieve test of test item was determined as per CIPAC MT 59, “Dry Sieve test”. The dry sieve test with the test item was carried out in single replicate. The sieve with 75 µm size retained ≥ 90 % of the particles; the sieve with 750 µm size, retained ≤ 10 % of the particles.

Conclusion

D50: 75 - 250 µm

Description of key information

D50: 75 - 250 µm

Additional information

CIPAC MT 59 - Dry sieve test