Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 2012
Reliability:
2 (reliable with restrictions)
Principles of method if other than guideline:
Internal method : Sieving and laser measurement
First sieving at 500µm. The undersized residue is analyzed with the laser method
Type of method:
sieving
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
No.:
#1
Size:
< 10 µm
Distribution:
ca. 0.1 %
No.:
#2
Size:
>= 10 - < 100 µm
Distribution:
ca. 0.6 %
No.:
#3
Size:
>= 100 - < 500 µm
Distribution:
ca. 3 %
No.:
#4
Size:
> 500 µm
Distribution:
ca. 96.3 %
Conclusions:
The large majority of the particles is above 500µm
Executive summary:

The large majority of the particles is above 500µm

Description of key information

According to the Particule size distribution (OECD No. 110 method)  it was shown that the majority of the particles obtained from the preliminary test between 100 µm and 1 mm (76.2%) was higher than 355 µm. It represents 43.3% of the total mass of the particles

Additional information