Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
Nov 2017 - Jan 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
Version / remarks:
Jul 2013
Deviations:
yes
Remarks:
decision criteria
Qualifier:
according to guideline
Guideline:
EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
Version / remarks:
Dec 2010
Deviations:
yes
Remarks:
decision criteria
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
p-menth-1-en-4-ol
EC Number:
209-235-5
EC Name:
p-menth-1-en-4-ol
Cas Number:
562-74-3
Molecular formula:
C10H18O
IUPAC Name:
4-methyl-1-(propan-2-yl)cyclohex-3-en-1-ol
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source: BASF SE, Ludwigshafen, Germany
- Batch No.of test material: 01767-1010
- Identity: Confirmed
- Purity: 97.3%
- Expiry date: 17 Mar 2019
- Physical state / color: Liquid / colorless, clear
- pH value: ca. 5 (undiluted test substance)

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature; under light exclusion
- Stability under test conditions: The stability was guaranteed
- Homogeneity: The test substanc was homogeneous by visual inspection

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: The test substance was applied undiluted, thus, no preparation was necessary.

Test animals / tissue source

Species:
other: Isolated bovine cornea
Strain:
other: not applicable
Details on test animals or tissues and environmental conditions:
SOURCE OF COLLECTED EYES
- Source: Schlachthof Alzey, Emil Färber GmbH & Co. KG, Robert-Bosch-Strasse 23, 55232 Alzey, Germany
- Characteristics of donor animals (age): minimum 12 months, maximum 60 months
- Detailed information of ocular tissue: Bovine eyes are obtained as a by-product of freshly slaughtered cattle

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent no treatment
yes, concurrent positive control
Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 750 µl
- Concentration (if solution): undiluted test substance

VEHICLE
- not applicable

CONTROLS
- Amount(s) applied (volume or weight with unit): 750 µl
Details on study design:
SELECTION AND PREPARATION OF CORNEAS

QUALITY CHECK OF THE ISOLATED CORNEAS: yes

NUMBER OF REPLICATES: 3

NEGATIVE CONTROL USED: yes

POSITIVE CONTROL USED: yes

APPLICATION DOSE AND EXPOSURE TIME: 750 µl, 10 min

TREATMENT METHOD: not specified

POST-INCUBATION PERIOD: yes/no. If YES please specify duration

REMOVAL OF TEST SUBSTANCE
- Number of washing steps after exposure period: 3
- POST-EXPOSURE INCUBATION: 2 hours

METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: Opacitometer
- Corneal permeability: passage of sodium fluorescein dye measured with the aid of UV/VIS spectrophotometry (OD490)

SCORING SYSTEM: In Vitro Irritancy Score (IVIS)

DECISION CRITERIA: see "any other information on materials and methods"

Results and discussion

In vitro

Resultsopen allclose all
Irritation parameter:
in vitro irritation score
Run / experiment:
cornea number 19
Value:
28.1
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
other: no indication of corrosive potential
Irritation parameter:
in vitro irritation score
Run / experiment:
cornea number 20
Value:
26.2
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
other: no indication of corrosive potential
Irritation parameter:
in vitro irritation score
Run / experiment:
cornea number 21
Value:
24.8
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
other: no indication of corrosive potential

Any other information on results incl. tables

Table 1: Opacity score of the test substance, the negative control and the positive control

Test substance

identification

 

Cornea- No.

 

Initial opacity

 

Final opacity

 

Opacity Change

Corrected Opacity

Change

 

Mean

 

SD

 

19

4.5

21.3

16.8

10.6

 

 

17/0495-1

20

3.7

17.0

13.3

7.2

9.0

1.7

 

21

3.8

18.9

15.2

9.0

 

 

 

10

3.9

11.0

7.1

NA

 

 

NC

11

2.8

7.6

4.8

NA

6.1

1.2

 

12

4.0

10.5

6.5

NA

 

 

 

13

4.7

32.7

27.9

21.8

 

 

PC1

14

2.8

34.3

31.6

25.4

21.9

3.5

 

15

4.6

29.0

24.5

18.3

 

 

 

16

5.3

109.4

104.1

98.0

 

 

PC2

17

5.2

97.5

92.3

86.2

93.7

6.5

 

18

3.8

106.8

103.0

96.8

 

 

Table 2: Permeability score of the test substance, the negative and the positive control

Test

substanceidentification

 

Cornea-No.

 

MeanOD490

 

DilutionFactor

Mean

CorrectedOD490

 

Mean

 

SD

 

19

1.170

1

1.165

 

 

17/0495-1

20

1.270

1

1.266

1.161

0.107

 

21

1.057

1

1.053

 

 

 

10

0.002

1

NA

 

 

NC

11

0.004

1

NA

0.004

0.003

 

12

0.007

1

NA

 

 

 

13

0.986

1

0.982

 

 

PC1

14

0.552

1

0.548

0.734

0.223

 

15

0.677

1

0.672

 

 

 

16

0.217

1

0.212

 

 

PC2

17

0.559

1

0.555

0.388

0.171

 

18

0.401

1

0.397

 

 

Table 3: In Vitro Irritancy Score (IVIS) of the test substance, the negative and the positive control

Test

substanceidentification

Cornea- No.

Opacity per cornea

Permeability per cornea

 

per cornea

IVIS

per group

mean

SD

 

19

10.6

1.165

28.1

 

 

17/0495-1

20

7.2

1.266

26.2

26.4

1.7

 

21

9.0

1.053

24.8

 

 

 

10

7.1

0.002

7.2

 

 

NC

11

4.8

0.004

4.8

6.2

1.2

 

12

6.5

0.007

6.6

 

 

 

13

21.8

0.982

36.5

 

 

PC1

14

25.4

0.548

33.6

32.9

4.1

 

15

18.3

0.672

28.4

 

 

 

16

98.0

0.212

101.1

 

 

PC2

17

86.2

0.555

94.5

99.5

4.4

 

18

96.8

0.397

102.8

 

 

Applicant's summary and conclusion

Interpretation of results:
Category 2 (irritating to eyes) based on GHS criteria
Conclusions:
Based on the results of the BCOP and EpiOcular Tests and by applying the evaluation criteria, it was concluded that the test substance shows an eye irritation potential in the in vitro eye irritation test strategy under the test conditions chosen.
Executive summary:

The objective was to assess the eye irritating potential of the test substance. By using the methods currently available a single in vitro assay is not sufficient to cover the full range of eye irritating potential. Therefore, two in vitro assays were part of this in vitro eye irritation test strategy: The Bovine Corneal Opacity and Permeability Test (BCOP Test) and EpiOcular Eye Irritation Test.

BCOP

The potential of the test substance to cause ocular irritation or serious damage to the eyes was assessed by a single topical application of 750 μL undiluted test substance to the epithelial surface of isolated bovine corneas. Three corneas were treated with the test substance for 10 minutes followed by a 2-hour postincubation period.

In addition to the test substance, a negative control (NC; deionized water) and two positive controls (PC1 / PC2; 100% ethanol / 100% dimethylformamide) were applied to three corneas each.

Corneal opacity was quantitatively measured as the amount of light transmitted through the cornea. Permeability was quantitatively measured as the amount of sodium fluorescein dye that passes across the full thickness of the cornea. Both measurements were used to calculate an In Vitro Irritancy Score of the test substance.

The following results were obtained in the BCOP Test:

 

Test substance identification

 

MeanOpacityValue

 

MeanPermeabilityValue

 

Mean In Vitro Irritancy Score

Test substance

9.0

1.161

26.4

NC

6.1

0.004

6.2

PC1

21.9

0.734

32.9

PC2

93.7

0.388

99.5