Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Jan 9, 2015 - Jan 15, 2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Version / remarks:
EC REGULATION No 440/2008
Deviations:
no
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Number of fragments:
6
Remarks on result:
not thermal sensitive if heated under defined confinement
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N

Table 1:Data of thermal sensitivity test

Series No

Mass of sample (g)

Diameter of orifice (mm)

Fragment effect of tubes

Test result

1

23.11

6.0

O

No explosion

2

23.03

6.0

O

No explosion

3

23.11

6.0

O

No explosion

4

23.08

2.0

O

No explosion

5

23.07

2.0

O

No explosion

6

23.11

2.0

O

No explosion

Test result: No explosion occurred in the test.

Test conclusion: the tested sample does not present a danger of explosion under the effect of a flame.

O: Tube unchanged

Table 2: Data of shock sensitivity test

Series No

Drop Weight

(Kg)

Drop height

(cm)

Impact energy

(J)

Test results

1

10

40

40

No reaction

2

10

40

40

No reaction

3

10

40

40

No reaction

4

10

40

40

No reaction

5

10

40

40

No reaction

6

10

40

40

No reaction

Test result: No explosion occurred in the test

Test conclusion: the tested sample does not present a danger of explosion under the mechanical shock conditions.

Table 3: Data of friction sensitivity test.

Series No

Weight number

Notch number

Friction load/ N

Test results

1

9

VI

360

No reaction

2

9

VI

360

No reaction

3

9

VI

360

No reaction

4

9

VI

360

No reaction

5

9

VI

360

No reaction

6

9

VI

360

No reaction

Test result: No explosion occurred in the test

Test conclusion: the tested sample does not present a danger of explosion under the mechanical friction conditions.

Interpretation of results:
GHS criteria not met
Conclusions:
According to EU A.14 test method, Everlan SL65 was not considered to present a danger of explosion. Therefore, Everlan SL65 was not met GHS criteria.
Executive summary:

The explosive properties of Everlan SL65 was determined according to EC REGULATION No 440/2008 Annex A.14 explosive properties. Everlan SL65 does not present a danger of explosionin the thermal sensitivity (effect of a flame) test and mechanical sensitivity (shock and friction) test. Therefore, Everlan SL65 was not considered to present a danger of explosion.

Description of key information

Everlan SL65 was not considered to present a danger of explosion (EC A.14).

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Everlan SL65 did not present a danger of explosion in the thermal sensitivity (effect of a flame) test and mechanical sensitivity (shock and friction) test. Therefore, Everlan SL65 was not considered to present a danger of explosion.

Justification for classification or non-classification