Reference
Endpoint:
explosiveness, other
Type of information:
other: theoretical assessment
Adequacy of study:
supporting study
Study period:
23 September - 16 November 2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Theoretical assessment following guideline 440/2008 EC A14
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
- Analytical purity: 94.55 %
- Expiration date: 31 December 2017
- Storage condition: at room temperature
Remarks on result:
other: Result based on a theoretical assessment

The test substance does not have any groups with explosive potential.

The oxygen balance was: -265.05 (C20) and -273.56 (C24).

An oxygen balance of >-200 indicates explosive potential. It is therefore concluded that the test substance does not exhibit explosive properties.

Interpretation of results:
GHS criteria not met
Conclusions:
The substance is concluded not to be explosive.

Description of key information

Based on a theoretical assessment following guideline 440/2008 EC A14 (Foster, 2016), the substance is considered to be not explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

Based on an theoretical expert statement, the substance does not contain any groups with explosive potential. Furthermore, the oxygen balance is < -200 which confirms the statement that the test substance does not have explosive properties.