Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-08-29
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
GLP compliance:
not specified
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
133.91 µm
Remarks on result:
not determinable
Key result
Percentile:
D10
Mean:
62.72 µm
Remarks on result:
other: SD not determined
Key result
Percentile:
D25
Mean:
117.8 µm
Remarks on result:
other: SD not determined
Key result
Percentile:
D50
Mean:
242.13 µm
Remarks on result:
other: SD not determined
Key result
Percentile:
D75
Mean:
415.73 µm
Remarks on result:
other: SD not determined
Key result
Percentile:
D90
Mean:
591.98 µm
Remarks on result:
other: SD not determined
Key result
Percentile:
other: D100
Mean:
1 030 µm
Remarks on result:
other: SD not determined
Conclusions:
26 % of the particles have a diameter < 125 µm, 13 % < 71µm.
As the substance is highly water soluble (>100g/l), particles inhaled are quickly solved.
Executive summary:

26 % of the particles have a diameter < 125 µm, 13 % < 71µm.

As the substance is highly water soluble (>100g/l), particles inhaled are quickly solved.

Description of key information

26 % of the particles have a diameter < 125 µm, 13 % < 71µm.

Additional information

According to company data of AlzChem (2018) 26 % of the particles of Guanidine Nitrate have a diameter < 125 µm, 13 % < 71µm. As the substance is highly water soluble (>100g/l), particles inhaled are quickly solved.