Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 930-915-9 | CAS number: 1318-02-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Description of first aid measures
General information: Take note of the following instructions
After inhalation: Supply fresh air; consult doctor in case of complaints.
After skin contact: Generally the product does not irritate the skin. Wash with water.
After eye contact: Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
After swallowing: If symptoms persist consult doctor.
Most important symptoms and effects, both acute and delayed
No further relevant information available.
Indication of any immediate medical attention and special treatment needed
No further relevant information available.
Fire-fighting measures
Extinguishing media
Suitable extinguishing agents: Use fire extinguishing methods suitable to surrounding conditions.
Special hazards arising from the substance or mixture
No further relevant information available.
Advice for firefighters
Protective equipment: Wear personal protective equipment.
No special measures required.
Additional information: Dispose of fire debris and contaminated fire fighting water in accordance with official regulations.
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Wear protective clothing
Environmental precautions
Do not allow product to reach sewage system or any water course.
Inform respective authorities in case of seepage into water course or sewage system.
Methods and material for containment and cleaning up
Sweep the spill area; avoid raising dust.
Handling and storage
Precautions for safe handling
Prevent formation of dust.
Keep receptacles tightly sealed.
Provide suction extractors if dust is formed.
Any unavoidable deposit of dust must be regularly removed.
Prevent static electric sparks.
Information about fire and explosion protection: Earth container to avoid electric sparks, especially in contact with flammable substances.
The product is not flammable.
Conditions for safe storage, including any incompatibilities
· Requirements to be met by storerooms and receptacles: No special requirements.
· Information about storage in one common storage facility: Store away from foodstuffs.
· Further information about storage conditions: Keep container tightly sealed. Store in dry conditions. This product is hygroscopic.
Specific end use(s)
No further relevant information available.
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- not applicable
Shippingopen allclose all
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- not applicable
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- not applicable
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- not applicable
Shippingopen allclose all
Remarksopen allclose all
Additional transport information
Additional information
- Special provisions / remarks / other:
- Not dangerous according to the above specifications.
For air tansport air freight only is recommended.
Exposure controls / personal protection
General protective and hygienic measures
The usual precautionary measures are to be adhered to when handling chemicals.
Respiratory protection
If the WEL value is exceeded.
Filter P2
Hand protection
Wear gloves for protection against mechanical hazards according to EN 388.
Check the condition of the gloves prior to each use.
Check the permeability prior to each anew use of the glove.
Use gloves of stable material (e.g. Nitrile) - if necessary tri-coted to improve the wearability.
Preventive skin protection by use of skin-protecting agents is recommended.
After use of gloves apply skin-cleaning agents and skin cosmetics.
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation.
Material of gloves: EN 388
Minimum requirements for efficiency level 1 for all groups. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.
Butyl rubber, BR or Nitrile rubber, NBR gloves
Recommended thickness of the material: ≥ 0.11 mm
Penetration time of glove material: EN 420: Minimum requirements for efficiency level 1 for all groups.
The exact break-through time has to be obtained from the manufacturer of the protective gloves and has to be observed.
For the mixture of chemicals mentioned here the penetration time has to be at least 480 minutes (Permeation according to EN 16523-1:2015: Level 6).
For the permanent contact in work areas without heightened risk of injury (e.g. Laboratory) gloves made of the following material are suitable:
Butyl rubber, BR
Nitrile rubber, NBR
For the permanent contact gloves made of the following materials are suitable:
Butyl rubber, BR
Nitrile rubber, NBR
Not suitable are gloves made of the following materials:
cloth gloves
Leather gloves
Eye/face protection
Safety glasses.
Body protection
Protective work clothing.
Stability and reactivity
Reactivity: No further relevant information available.
Chemical stability: No decomposition if used and stored according to specifications.
Possibility of hazardous reactions: No dangerous reactions known.
Conditions to avoid: No further relevant information available.
Incompatible materials: No further relevant information available.
Hazardous decomposition products: No dangerous decomposition products known.
Disposal considerations
Waste treatment methods
Recommendation: Disposal must be made according to official regulations.
Waste disposal key: The disposal of the product has to be carried out in accordance with the legal requirements.
EWC waste codes are strictly industry-oriented, therefore waste classification has to be done by the waste producer.
Uncleaned packaging: Disposal must be made according to official regulations.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.