Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 257-098-5 | CAS number: 51274-00-1 This substance is identified in the Colour Index by Colour Index Constitution Number, C.I. 77492.
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Link to relevant study record(s)
- Endpoint:
- basic toxicokinetics in vitro / ex vivo
- Remarks:
- Bioaccessibility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2018-02-26 to 2018-09-26
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Objective of study:
- bioaccessibility (or bioavailability)
- Qualifier:
- according to guideline
- Guideline:
- OECD Series on Testing and Assessment No. 29 (23-Jul-2001): Guidance document on transformation/dissolution of metals and metal compounds in aqueous media
- Principles of method if other than guideline:
- An internationally agreed guideline does not exist for this test (e.g. OECD). However, similar tests have been conducted with several metal compounds in previous risk assessments (completed under Regulation (EEC) No 793/93) and in recent preparation for REACH regulation (EC) No 1907/2006. The test was conducted on the basis of the guidance for OECD-Series on testing and assessment Number 29 and according to the bioaccessibility test protocol provided by the study monitor. The test media were artificial physiological media: gastric fluid (GST), phosphate-buffered saline (PBS), artificial lysosomal fluid (ALF) and Gamble's solution (GMB)
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- signed 2016-05-31
- Radiolabelling:
- no
- Species:
- other: in vitro (simulated human body fluids)
- Details on test animals or test system and environmental conditions:
- Test principle in brief:
- four different artificial physiological media,
- single loading of test substance of ~100 mg/L,
- GST and PBS media: samples taken after 2 and 24 hours agitation (100 rpm) at 37 ± 2 °C
- GMB and ALF media: samples taken after 2, 24 and 168 hours agitation (100 rpm) at 37 ± 2 °C
- two additional method blanks per medium, measurement (ICP-OES) of dissolved Fe concentrations after filtration and centrifugal filtration.
- the study was performed in triplicate
The aim of this test was to assess the dissolution of iron hydroxide oxide yellow (Sicovit Yellow 10 E172) in four artificial physiological media: Phosphate buffered saline (PBS, pH 7.2-7.4), Artificial gastric fluid (GST, 1.5-1.6), artificial lysosomal fluid (ALF) and Gamble’s solution (GMB). The test media were selected to simulate relevant human-chemical interactions (as far as practical), e.g. a substance entering the human body by ingestion into the gastro-intestinal tract (GST) or via the respiratory system (ALF). - Duration and frequency of treatment / exposure:
- Iron concentrations in GST and PBS were determined after 2 and 24 h whereas iron concentrations in GMB and ALF media were assessed after 2, 24 and 168 hours of incubation.
- Dose / conc.:
- 100 other: mg of test item/L artificial media
- Details on study design:
- Test setup
Three replicate flasks (500 mL glass flasks) per test medium (PBS, GST) were prepared with a loading of ~ 100 mg/L. The test item was weighed into flasks, adjusted to volume with the respective artificial physiological medium and agitated at 100 rpm at 37°C ± 2°C. Two control blank replicates (same procedure) per test medium were also prepared.
Three replicates containing the test item and two method blanks per artificial medium were tested. All solutions were sampled after 2 and 24 h whereas GMB and ALF media were also sampled after 168h to measure total dissolved Fe concentrations (ICP-OES) after 0.2 µm filtration (Syringe Filter w / 0.2 μm, polyethersulfon membrane, DIA Nielsen, Dueren, Germany) and centrifugal filtration (i.e. 0.2 μm filtration and 3kDa centrifugal filtration, Sartorius, Göttingen, Germany). In addition, temperature, pH and observations, including the appearance of the solution (including colour, turbidity and particle film on the surface) were recorded.
Sample fortification:
In addition, samples of the artificial physiological media were fortified with a known amount of iron (by standard addition of commercial standards) to determine the standard recovery. For detailed information please refer to "Any other information on materials and methods incl. tables".
Mass balance:
After the test, aqua regia (3 : 1 mixture of concentrated hydrochloric and nitric acid) was added to the vessels containing the test item to reach a final volume of 500 mL, i.e. 120 mL aqua regia were added to approximately 380 mL GST or PBS medium, 180 mL aqua regia were added to approximately 320 mL ALF or GMB medium. From these solutions, 50 mL were taken after 3 - 14 days of “digestion” for mass balance determination.
The filters (Syringe Filter w / 0.2 μm, polyethersulfon membrane, DIA Nielsen, Dueren, Germany) used for sampling were extensively rinsed with a known volume of aqua regia (ca. 2.5 mL). The added aqua regia was let to drop slowly through the filters and was collected in a clean vial. This procedure was repeated with every syringe and filter used during the study. After collection, the volume was filled up to exactly 10 mL (for the media GST and PBS) and up to 15 mL (for the ALF and GMB media) with aqua regia. Afterwards the concentration of iron in the “filtrated” aqua regia was determined and considered for the determination of the mass balances.
Reagents:
Purified water (resistivity > 18 MΩ·cm, Pure Lab Ultra water purification system from ELGA LabWater, Celle, Germany)
Nitric acid - “Supra” quality (ROTIPURAN® supplied by Roth, Karlsruhe, Germany).
Hydrochloric acid – “Baker-instra-analyzed-plus” quality (J.T. Baker, Griesheim, Germany).
Sodiumhydroxide – pro Analysis quality (Chemsolute, Th. Geyer, Renningen, Germany)
MgCl2 x 6H2O (p.A., Merck, Darmstadt, Germany)
NaCl (p.A., Chemsolute, Renningen, Germany + Merck, Darmstadt, Germany (new GMB medium))
KCl (p.A., Chemsolute, Renningen, Germany + Merck, Darmstadt, Germany (new GMB medium))
Na2HPO4 (p.A. Merck, Darmstadt, Germany)
Na2SO4 (p.A. Merck, Darmstadt, Germany)
CaCl2 x 2H2O (p.A. Merck, Darmstadt, Germany)
NaAcetate (suprapur Merck, Darmstadt, Germany)
NaHCO3 (p.A. Merck, Darmstadt, Germany)
NaOH (p.A., Chemsolute, Renningen, Germany)
Citric acid anhydrous (p.A., Roth, Karlsruhe, Germany)
Glycine (p.A., Merck, Darmstadt, Germany)
Na3Citrate x 2H2O (p.A., Merck, Darmstadt, Germany)
Na2Tartrate x 2H2O (p.A., Merck, Darmstadt, Germany)
NaLactate (98+% Sigma Aldrich, Munich, Germany)
NaPyruvate (p.A., Applichem, Darmstadt, Germany)
KH2PO4 (p.A., Merck, Darmstadt, Germany)
Urea (pure, Applichem, Darmstadt, Germany)
Lactic acid (purum, Fluka, Munich, Germany)
HCl 30% (instra-analyzed, plus J.T. Baker, Griesheim, Germany)
METAL ANALYSIS
- Standards for metal analysis: A commercially available single element standard was used as iron standard (Merck Certipur Iron ICP standard 1000 mg/L lot no. HC68868126; Darmstadt, Germany) to prepare an appropriate stock solution and subsequently calibration solutions for ICP-OES measurements
- Certified reference materials: As quality control standards, certified aqueous reference material TM-DWS.3 (lot no. 0916) and TMDA-70.2 (lot no. 0916 and 0917) obtained from Environment Canada and a multielement standard (Merck Certipur IV ICP standard 1000 mg/L lot no. HC54938555 and HC73962555; Darmstadt, Germany) were analysed for total dissolved iron by ICP-OES.
Instrumental and analytical set-up for the ICP-OES instrument:
Agilent 720, Agilent Technologies, Waldbronn, Germany
Nebulizer: Sea spray nebulizer, from Glass Expansion
Spray chamber: Iso Mist with Twister Helix from Glass Expansion
Plasma stabilization time: at least 30 min before start of the measurements
Plasma gas flow: 15.0 L/min
Additional gas flow: 1.50 L/min
Carrier gas flow: 0.75 L/min
RF power: 1200W
Stabilization time of sample: 15 sec
Repetition time (three internal measurements per sample): 30 sec
Wavelengths: Fe: 238.204 nm, 240.489 nm, 241.052 nm, 258.588 nm and 259.940 nm
- Correlation coefficients (r) for the wavelengths used for evaluation of data were at least >0.999603
The applied LOD/LOQ calculations for the Agilent 720 ICP-OES:
LOD: 3 * standard deviation of calibration blank/slope of the calibration
LOQ: 3 * LOD
The resulting LODs/LOQs are reported in "Any other information on results incl. tables" - Details on dosing and sampling:
- Loading:
Detailed loadings of the test vessels are given in "Any other information on materials and methods incl. tables". - Type:
- other: Bioaccessibility ALF, 2h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- 6.96 µg Fe/L (dissolved)
- Type:
- other: Bioaccessibility ALF, 24h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- 29 µg Fe/L (dissolved)
- Type:
- other: Bioaccessibility ALF, 168h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- 80.5 µg Fe/L (dissolved)
- Type:
- other: Bioaccessibility GST, 2h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- 2.24 µg Fe/L (dissolved)
- Type:
- other: Bioaccessibility GST, 24h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- 55.9 µg Fe/L (dissolved)
- Type:
- other: Bioaccessibility GMB, 2h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- negative value after correction
- Type:
- other: Bioaccessibility GMB, 24h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- 0.258 µg Fe/L (dissolved)
- Type:
- other: Bioaccessibility GMB, 168h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- negative value after correction
- Type:
- other: Bioaccessibility PBS, 2h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- < LOD/LOQ (1.54 µg Fe/L)
- Type:
- other: Bioaccessibility PBS, 24h @ 37°C (100 mg/L loading, 0.2 µm + 3 kDa filtration for phase separation)
- Results:
- < LOD (0.761 µg Fe/L)
- Bioaccessibility (or Bioavailability) testing results:
- Please refer to "any other information on results incl. tables" below.
- Conclusions:
- The bioaccessibility of iron hydroxide oxide yellow (Sicovit yellow 10 E172) was determined in vitro by simulating dissolution under physiological conditions considered to mimic artificial body fluids with a loading of 100 mg test item/L. After 2 and 24 h in phosphate buffered saline (PBS, pH 7.2-7.4) solution, dissolved iron concentrations (operationally defined as the dissolved Fe fraction after 0.2 µm filtration and centrifugal filtration (~2.1 nm)) were at least below the LOQ (<1.54 µg/L). With mean concentrations of 0.258 µg Fe/L after 24 h and negative values (after subtraction of background) after 2 and 168 h, dissolved iron concentrations in Gamble´s solution (GMB, pH 7.4) were also very low. In artificial gastric fluid (GST, pH 1.5-1.6), 2.24 µg Fe/L and 55.9 µg Fe/L were detected in the dissolved phase after 2 and 24 h, respectively. Mean iron concentrations were highest in artificial lysosomal fluid (ALF, pH 4.5): 6.96 µg/L, 29.0 µg/L and 80.5 µg/L of iron were found in the dissolved phase after 2, 24 and 168 h. Therefore, with a maximum mean released fraction of <0.1% after 168 h, the dissolution of iron hydroxide oxide yellow (Sicovit Yellow 10 E172) was highest in artificial lysosomal fluid (ALF).
- Endpoint:
- basic toxicokinetics in vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2018-09-11 to 2019-06-21
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Objective of study:
- toxicokinetics
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 417 (Toxicokinetics)
- Version / remarks:
- 2010-07-22
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- signed 2017-05-08
- Specific details on test material used for the study:
- STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: stored in tightly-closed, original container, at ambient temperature, kept dry. - Radiolabelling:
- no
- Species:
- rat
- Strain:
- other: Crl:CD(SD)
- Details on species / strain selection:
- The rat is a commonly used rodent species for toxicity studies.
- Sex:
- male/female
- Details on test animals or test system and environmental conditions:
- TEST ANIMALS
- Source: Charles River Laboratories Research, Models and Services Germany GmbH, Sandhofer Weg 7, 97633 Sulzfeld, Germany
- Age at study initiation: 59 to 60 days
- Weight at study initiation: males: 262 g to 340 g; females: 200 g to 272 g
- Housing: kept in groups of up to 3 animals (same sex) in MAKROLON cages (type IV) with a basal surface of approximately 55 cm × 33 cm and a height of approximately 20 cm; bedding material: granulated textured wood
- Diet (ad libitum): Commercial diet, ssniff® R/M-H V1534
- Water (ad libitum): drinking water
- Acclimation period: 14 days
ENVIRONMENTAL CONDITIONS
- Temperature: 22°C ± 3°C (maximum range)
- Relative humidity: 55% ± 10% (maximum range)
- Photoperiod (hrs dark / hrs light): 12/12 - Route of administration:
- other: Sicovit Yellow 10 E172: oral (gavage); reference item: intravenously injected
- Vehicle:
- other: Sicovit Yellow 10 E172: 0.5 % aqueous hydroxypropylmethylcellulose gel; reference item: 0.9 % NaCl solution
- Details on exposure:
- PREPARATION OF DOSING SOLUTIONS:
1) Sicovit Yellow 10 E172:
The test items were suspended or dissolved in the vehicle to the appropriate concentration freshly on the administration day and were administered orally by gavage at a constant volume (adminsitration volume: 10 mL/kg bw). The application formulations were continuously agitated by stirring throughout the entire administration procedure.
2) Reference item (Iron (III) citrate tribasic monohydrate; Fe content: 21.2%)
Prior to administration, the reference item and the appropriate vehicle were heated to 70°C and stirred at 50°C for approx. 3 hours until the reference item was completely dissolved. This clear solution was maintained at room temperature until administration. The status as clear solution was monitored and recorded upon administration. Immediately after formulation preparation for the females, the formulations were protected from light by transferring the formulation into brown containers or wrapping in aluminium foil.
The amounts of the test and reference items were adjusted to the animal's current body weight on the administration day.
Administration volume (oral administration / intravenous administration): 10 mL/kg bw/day
Injection speed (intravenous adminsitration): dose per approx. 15 seconds - Duration and frequency of treatment / exposure:
- single administration
- Dose / conc.:
- 1 000 mg/kg bw/day (actual dose received)
- No. of animals per sex per dose / concentration:
- 5 males / 5 females
- Control animals:
- yes, concurrent vehicle
- Positive control reference chemical:
- none
- Details on study design:
- - Dose selection rationale: the dose levels for this study were selected after consultation with the sponsor based on available toxicity and bioavailability data (as far as available):
1) Reference item (Iron (III) citrate tribasic monohydrate; Fe content: 21.2%):
The oral LD50 value for iron citrate monohydrate was stated as being >2000 mg/kg bw; the oral bioavailability of soluble Fe substances are given in the public domain with 1 to 26% (Fe).
For the test item oral dosing of 1000 mg/kg bw, a very low relative bioavailability was assumed (<1%), considering the very low water solubility and bioacessibility in gastric juice. Since the four iron oxide test items have Fe-contents of approx. 70%, the dose of the reference substance should be adjusted accordingly. Given a test item dose of 1000 mg/kg b.w. (corresponding to 700 mg Fe/kg bw), then 1% of this dose would correspond to 7 mg Fe/kg bw (or 36.8 mg/kg bw iron citrate). Correcting for approx. 20% oral bioavailability of soluble iron substances, this yields a dose for the reference item of 7.4 mg iron citrate/kg bw to be given by intravenous injection.
2) Sicovit Yellow 10 E172:
The test item oral doses of 1000 mg/kg bw correspond to the limit dose used in a separate 90-day oral toxicity study, which was considered the maximum feasible dose. This dose was also selected in view of the anticipated low bioavailability and the requirements of analytical sensitivity of the analytical method for iron in plasma.
3) Vehicle control group:
In view of the long established circadian variation of plasma iron levels (Lynch et al, 1973)*, a vehicle control group was sampled for blood plasma over a period of 24 hours at identical sampling time points and intervals as the dosed groups.
*Reference:
Lynch et al (1973): Circadian Variation in Plasma Iron Concentration and Reticuloendothelial Iron Release in the Rat, Clinical Science and Molecular Medicine (1973) 45, 331-336. - Details on dosing and sampling:
- TOXICOKINETIC / PHARMACOKINETIC STUDY (Absorption, distribution, excretion)
- Tissues and body fluids sampled: plasma
- Time and frequency of sampling: blood was collected 0 (predose), 0.5, 1, 2, 4, 8, 12, 24, 48 (test item and reference item only), and 72 hours (test item and reference item only) after administration. The whole blood samples were cooled using an IsoTherm-Rack system until centrifugation. Immediately after centrifugation, the isolated plasma was frozen at -20°C ± 10 % and stored at this temperature until analysis.
Pharmacokinetic evaluation of plasma data was performed and a non-compartment model was employed. The following parameters were determined, if possible:
AUC0-∞ = extrapolated area from zero to infinity
AUC0-t last = extrapolated area from time zero to the last quantifiable plasma concentration (i.e. >lower limit of quantification, LLOQ)
Kel = elimination rate constant
t1/2 = elimination half-life
Cmax values were the highest measured plasma concentrations and tmax values were the time points of highest plasma concentrations.
Elimination rate constants (Kel) and plasma elimination half-lives (t½) were calculated by linear regression analysis of the log/linear portion of the individual plasma concentration-time curves (c = concentration, t = time).
Area under the curve (AUC) values were calculated using the linear trapezoidal method and extrapolated to infinite time by dividing the last measurable plasma concentration by the elimination rate constant. Plasma concentrations at time zero were taken to be those at the first blood sampling time.
Furthermore, the AUC0-t last was calculated according to the linear trapezoidal rule. Values below the limit of quantification (LOQ) were excluded from calculation.
In addition, the bioavailability was calculated for the mixture.
For plasma, a pre-treatment by a microwave digestion with HNO3 was necessary to digest the proteins in plasma. Afterwards iron in digested samples was measured by ICP-OES.
OBSERVATIONS
- clinical signs: before and after dosing as well as regularly throughout the working day (7.30 a.m. to 4.30 p.m.) and on Saturdays and Sundays (8.00 a.m. to 12.00 noon; final check at approx. 4.00 p.m).
Special attention was paid to the local tolerance at the injection site(s).
- mortality/morbund: early in the morning and again in the afternoon of each working day as well as on Saturdays and Sundays (final check at approx. 4.00 p.m).
- body weight: at the time of group allocation, before dosing for dose adjustment and on test day 4 before the last blood sampling.
ADMINISTRATION FORMULATION ALANYSIS:
For each test item, that was mixed with the vehicle and the reference substance, tests by appropriate analytical methods were conducted to determine the concentration and stability of the test item in the formulations. For the analysis of the application formulations, one sample of exactly 10 mL from each dosing suspension (test items) or dosing solution (reference item) was taken at the start of the administration (test day 1 of the female animals) and frozen until analysis.
Application solutions of the iron oxide was measured after addition of aqua regia to the samples and after an incubation time for at least four days by ICP-OES. After this measurement the remaining precipitation (only iron oxide application solution) were digested by a microwave procedure and measured by ICP-OES.
ANALYTIC OF REFERENCE ITEM:
The iron content of the reference item (Iron (III) citrate tribasic monohydrate; Fe content: 21.2%) was determined using ICP-OES. - Statistics:
- The test item group was compared to the reference group. The following statistical method was used:
- Student's t-test (body weight (at p≤0.05 and p≤0.01; limits used p = 0.05 approx. t = 2.306 p = 0.01 approx. t = 3.355 (for 8 degrees of freedom)) - Preliminary studies:
- none
- Details on absorption:
- not specified
- Details on distribution in tissues:
- not specified
- Details on excretion:
- not specified
- Toxicokinetic parameters:
- other: bioavailability
- Remarks:
- An absolute bioavailability of 0.26%/0.21% (m/f) for Sicovit Yellow was calculated for Fe following oral administration compared to intravenous administration.
- Toxicokinetic parameters:
- other:
- Remarks:
- It should be noted that this evaluation was done on the substance-specific data without consideration of the vehicle control.
- Toxicokinetic parameters:
- other:
- Remarks:
- The plasma iron levels of the dosed group falls within the boundaries of the vehicle control group which reflects long established daily circadian variation of plasma iron levels.
- Toxicokinetic parameters:
- other:
- Remarks:
- The calculated absolute bioavailabiliy derived by the pharmacokinetic analysis can therefore be seen as conservative overestimates, thus leading to the conclusion that the bioavailability of iron from the tested oxide is similarly minimal to negligible.
- Metabolites identified:
- not measured
- Details on metabolites:
- not measured
- Bioaccessibility (or Bioavailability) testing results:
- An absolute bioavailability of 0.26%/0.21% (m/f) for Sicovit Yellow was calculated for iron following oral administration compared to intravenous administration. However, it should be noted that this evaluation was done on the substance-specific data without consideration of the vehicle control.
The plasma iron levels of the dosed group falls practically within the boundaries of the vehicle control group which reflects long established daily circadian variation of plasma iron levels. Hence, the calculated absolute bioavailabilities derived by the pharmacokinetic analysis can therefore be seen as conservative overestimates, thus leading to the conclusion that the bioavailability of iron from the tested oxide is similarly minimal to negligible.
Please also refer for results to the field "Attached background information" below. - Conclusions:
- An absolute bioavailability of 0.26%/0.21% (m/f) for Sicovit Yellow was calculated for iron following oral administration compared to intravenous administration. However, it should be noted that this evaluation was done on the substance-specific data without consideration of the vehicle control.
The plasma iron levels of the dosed group falls within the boundaries of the vehicle control group which reflects long established daily circadian variation of plasma iron levels. Hence, the calculated absolute bioavailability derived by the pharmacokinetic analysis can therefore be seen as conservative overestimates, thus leading to the conclusion that the bioavailability of iron from the tested oxide is similarly minimal to negligible.
Referenceopen allclose all
Iron concentrations in simulated artificial body fluids:
The bioaccessibility of Sicovit Yellow 10 E172 was determined in vitro by simulating dissolution under physiological conditions considered to mimic artificial body fluids with a loading of 100 mg test item/L. Dissolved iron concentrations were operationally defined as the dissolved Fe fraction after 0.2 µm filtration and centrifugal filtration (~2.1 nm), see Table 3. With a maximum mean released fraction of <0.1% after 168 h, dissolution of Sicovit Yellow 10 E172 was highest in artificial lysosomal fluid (ALF).
In addition, dissolved/dispersed mean iron concentrations (operationally defined as the dissolved Fe fraction after 0.2 µm filtration) are summarized in table 4.
Table 3: Iron concentrations of artificial physiological media (filtrated through a 0.2 µm membrane and centrifugally filtrated) after exposure to Sicovit Yellow 10 E172
medium&time |
LOD/LOQ o fFe measurement series |
Mean Fe±SD of method blanks |
Without background correction |
With background correction* |
|
|
|
Mean Fe±SD |
MeanFe |
GST2h |
LOD:0.677µg/L LOQ:2.03µg/L |
12.4±1.45µg/L |
14.6±2.91µg/L |
2.24µg/L |
GST24h |
LOD:0.689µg/L LOQ:2.07µg/L |
7.77±0.14µg/L(one method blank defined as outlier-excluded) |
63.7±11.0µg/L |
55.9µg/L |
GMB 2h |
LOD:0.206µg/L LOQ:0.619µg/L |
2.49±0.59µg/L |
2.29±0.08µg/L |
Negative value after correction |
GMB 24h |
LOD:0.190µg/L LOQ:0.570µg/L |
2.33±0.02µg/L |
2.59±1.03µg/L |
0.258µg/L |
GMB 168h |
LOD:0.242µg/L LOQ:0.725µg/L |
2.38±1.40µg/L |
1.99±0.70µg/L |
Negative value after correction |
ALF2h |
LOD:0.287µg/L LOQ:0.862µg/L |
10.3±1.01µg/L |
17.3±3.69µg/L |
6.96µg/L |
ALF24h |
LOD:0.886µg/L LOQ:2.66µg/L |
5.64±1.83µg/L |
34.6±1.44µg/L |
29.0µg/L |
ALF168h |
LOD:0.434µg/L LOQ:1.30µg/L |
4.92±0.48µg/L |
85.5±3.96µg/L |
80.5µg/L |
PBS 2h |
LOD:0.514µg/L LOQ:1.54µg/L |
All: <LOD(after outlier exclusion–one sample:>LOQ) |
All: <LOD/LOQ |
|
PBS 24h |
LOD:0.761µg/L LOQ:2.28µg/L |
All: <LOD |
All: <LOD |
|
*backgroundconcentration=meanofFeconcentrationsmeasuredafter 2h ,24 h or 168h
Table 4: Iron concentrations of artificial physiological media (filtrated through a 0.2 µm membrane) after exposure to
Sicovit Yellow 10 E172
medium&time |
LOD/LOQ of Fe measurement series |
Mean Fe±SD of method blanks |
Without background correction |
Withback groundcorrection* |
Mean Fe±SD |
MeanFe |
|||
GST2h |
LOD:0.677µg/L LOQ:2.03µg/L |
All: <LOQ |
11.7±1.91µg/L |
Nocorrection |
GST24h |
LOD:0.689µg/L LOQ:2.07µg/L |
2.42±0.91µg/L (1blank:<LOQ;3blanks:>LOQ) |
55.9±9.92µg/L |
53.5µg/L |
GMB 2h |
LOD:0.206µg/L LOQ:0.619µg/L |
0.724±0.023µg/L(1 blank:<LOD; 3blanks:>LOQ) |
Allsamples:<LOD/LOQ |
|
GMB 24h |
LOD:0.190µg/L LOQ:0.570µg/L |
All: <LOD/LOQ(after outlier exclusion) |
Allsamples:<LOD/LOQ |
|
GMB 168h |
LOD:0.242µg/L LOQ:0.725µg/L |
All: <LOD(after outlier exclusion) |
Allsamples:<LOD |
|
ALF2h |
LOD:0.287µg/L LOQ:0.862µg/L |
1.96±0.18µg/L |
11.1±0.93µg/L |
9.17µg/L |
ALF24h |
LOD:0.886µg/L LOQ:2.66µg/L |
All: <LOQ(after outlier exclusion) |
34.0±2.03µg/L |
No correction |
ALF168h |
LOD:0.434µg/L LOQ:1.30µg/L |
2.39±0.54µg/L |
89.8±2.74µg/L |
87.4µg/L |
PBS2h |
LOD:0.514µg/L LOQ:1.54µg/L |
All: <LOD(after outlier exclusion) |
All: <LOD |
|
PBS 24h |
LOD:0.761µg/L LOQ:2.28µg/L |
All: <LOD |
All:LOD |
*background concentration=mean of Fe concentrations measured after 2h ,24 h or 168h
Solution pH -GST
blank vessels
sample name |
target pH |
pH prior to the test |
pH after 2h |
pH after 24 h |
GSTblankvessel1 |
1.5–1.6 |
1.55 |
1.57 |
1.59 |
GSTblankvessel2 |
1.5–1.6 |
1.54 |
1.58 |
1.58 |
Sicovit Yellow 10 E172
sample name |
target pH |
pH prior to the test |
pH after 2h |
pH after 24h |
|
GSTvessel1 |
1.5–1.6 |
1.55 |
1.59 |
1.59 |
|
GSTvessel2 |
1.5–1.6 |
1.55 |
1.58 |
1.62 |
|
GSTvessel3 |
1.5–1.6 |
1.55 |
1.6 |
1.6 |
Solution pH - PBS
blank vessels
samplename |
targetpH |
pHpriortothetest |
pHafter2h |
pHafter24h |
PBSblankvessel1 |
7.2–7.4 |
7.30 |
7.30 |
7.33 |
PBSblankvessel2 |
7.2–7.4 |
7.30 |
7.33 |
7.33 |
Sicovit Yellow 10 E172
sample name |
target pH |
pH prior to the test |
pH after 2h |
pH after 24h |
PBS vessel 1 |
7.2–7.4 |
7.31 |
7.35 |
7.36 |
PBS vessel 2 |
7.2–7.4 |
7.29 |
7.32 |
7.32 |
PBS vessel 3 |
7.2–7.4 |
7.31 |
7.36 |
7.37 |
Solution pH - GMB
blank vessels
samplename |
targetpH |
pHpriortothetest |
pHafter2h |
pHafter24h |
pHafter7d |
GMBblankvessel1 |
7.4 |
7.46 |
8.10 |
8.68 |
9.09 |
GMBblankvessel2 |
7.4 |
7.46 |
8.14 |
8.74 |
9.09 |
Sicovit Yellow 10 E172
sample name |
target pH |
pH prior to the test |
pH after 2h |
pH after 24h |
pH after 7d |
GMBvessel1 |
7.4 |
7.44 |
8.17 |
8.72 |
9.17 |
GMBvessel2 |
7.4 |
7.45 |
8.26 |
8.86 |
9.22 |
GMBvessel3 |
7.4 |
7.45 |
8.10 |
8.77 |
9.19 |
Solution pH - ALF
blank vessels
samplename |
targetpH |
pHpriortothetest |
pHafter2h |
pHafter24h |
pHafter7d |
ALFblankvessel1 |
4.5 |
4.56 |
4.57 |
4.62 |
4.62 |
ALFblankvessel2 |
4.5 |
4.56 |
4.59 |
4.62 |
4.62 |
Sicovit Yellow 10 E172
sample name |
target pH |
pH prior to the test |
pH after 2h |
pH after 24h |
pH after 7d |
ALFvessel1 |
4.5 |
4.55 |
4.60 |
4.62 |
4.63 |
ALFvessel2 |
4.5 |
4.55 |
4.61 |
4.62 |
4.62 |
ALFvessel3 |
4.5 |
4.54 |
4.58 |
4.62 |
4.63 |
Test temperature:
With 37 °C ± 2 °C, the temperature was stable during the test for all solutions
Method validation summary (ICP-OES)
Limits of detection (LODs), limits of quantification (LOQs) and correlation coefficients (r)
Limits of detection (LOD) within all measurement series: < 1.24 µg Fe/ L.
Limits of quantification (LOQ) within all measurement series: < 3.73 µg Fe/ L.
Correlation coefficients (r) within all measurement series: >0.999603
GST
Mean recovery of fortified samples (n = 20): 98.6 - 104 %
Mean recoveries for certified reference materialTM-DWS.3andTMDA-70.2(concentration range 22.4 – 75.4 µg Fe / L, n = 24): 103 -105 %
Mean recoveries for quality control standard (concentration range 50 -500 µg Fe/ L, n = 24): 98.2 - 105 %
Mean recoveries for internal standard (concentration range 10 -300 µg / L, n = 24): 98.4 - 100 %
PBS
Mean recovery of fortified samples (n = 32): 90.5 - 108 %
Mean recoveries for certified reference materialTM-DWS.3andTMDA-70.2(concentration range 22.4 – 75.4 µg Fe / L, n = 20): 98.0-101 %
Mean recoveries for quality control standard (concentration range 5 -50 µg Fe/ L, n = 30): 97.0 – 99.9 %
Mean recoveries for internal standard (concentration range 10 -100 µg / L, n = 30): 97.5 – 99.8 %
GMB
Mean recovery of fortified samples (n = 48): 92.2 - 128 %
Mean recoveries for certified reference materialTM-DWS.3andTMDA-70.2(concentration range 22.4 – 75.4 µg Fe / L, n = 59): 95.5-107 %
Mean recoveries for quality control standard (concentration range 5 -50 µg Fe/ L, n = 60): 95.5 – 104 %
Mean recoveries for internal standard (concentration range 10 -100 µg / L, n = 60): 97.0 – 102 %
ALF
Mean recovery of fortified samples (n = 24): 85.5 - 106 %
Mean recoveries for certified reference materialTM-DWS.3andTMDA-70.2(concentration range 22.4 – 75.4 µg Fe / L, n = 48): 93.6-103 %
Mean recoveries for quality control standard (concentration range 5 -200 µg Fe/ L, n = 48): 96.1-100 %
Mean recoveries for internal standard (concentration range 10 -100 µg / L, n = 48): 95.0 – 106 %
Method validation – mass balance measurements
Mean recovery of fortified samples (n = 27): 89.4 - 106 %
Mean recoveries for certified reference materialTM-DWS.3andTMDA-70.2(concentration range 22.4 – 75.4 µg Fe / L, n = 30): 100-109 %
Mean recoveries for quality control standard (concentration range 250 -600 µg Fe/ L, n = 30): 100-103 %
Mean recoveries for internal standard (concentration range 100 -400 µg / L, n = 30): 100 – 106 %
LOCAL TOLERANCE (REFERENCE ITEM; INTRAVENOUS ADMINISTRATION):
No signs of local intolerance reactions were noted at the injection sites of any male or female animal treated intravenously with 7.4 mg/kg Iron(III) citrate (reference item).
CLINICAL SIGNS, MORTALITY, AND BODY WEIGHT:
1) Sicovit Yellow 10 E172:
- none of the animals died or had to be sacrificed prematurely. No signs of morbidity were noted.
- no signs of test item-related behavioural changes or abnormalities in the external appearance were noted for any male or female animal following single oral administration of Sicovit Yellow 10 E172 at a dose level of 1000 mg/kg bw.
- discolouration of the faeces (bright beige) was noted for all animals following single oral administration of the test item. The discolouration is however not considered a toxic effect, instead considered to be merely excretion of the respective test item.
- no test item-related changes were noted in body weight for any animal following single oral administration of Sicovit Yellow 10 E172 at a dose level of 1000 mg/kg bw. No statistically significant differences were noted comparing the test item-treated group with the control group. The body weights were within the normal biological range of animals of this age and strain.
2) Reference item (iron (III) citrate tribasic monohydrate):
- none of the animals died or had to be sacrificed prematurely. No signs of morbidity were noted.
- signs of toxicity were noted for the male animals treated intravenously with the reference item Iron(III) citrate tribasic monohydrate with 7.4 mg/kg bw.. Reduced motility was noted for four male animals starting approx. 0-5 min p.a., lasting approx. 5-20 min. For the remaining male animal reduced motility was observed slightly longer with approx. 20-60 min accompanied with being in prone position. The female animals treated intravenously with the reference item did not reveal any abnormalities.
3) Vehicle control group:
- no signs of behavioural changes or abnormalities in the external appearance for any male or female animal following single oral administration of 0.5% aqueous hydroxypropylmethyl-cellulose gel were noted.
PHARMACOKINETIC EVALUATION
1) Reference item (iron (III) citrate tribasic monohydrate):
Cmax-levels in plasma of 6.28 μg Fe/g and 5.81 μg Fe/g were noted 0 to 1 hour (tmax as range m/f) after intravenous administration of 7.4 mg Iron(III) citrate/kg bw for the male and female rats on test day 1, respectively.
2) Sicovit Yellow 10 E172:
Furthermore, Cmax-levels in plasma of 3.59 μg Fe/g and 3.76 μg Fe/g were noted 2 to 72 hours (tmax as range m/f) after oral administration of 1000 mg Sicovit Yellow/kg bw for the male and female rats on test day 1, respectively.
TEST ITEM FORMULATION ANALYSIS:
The results of the analysis showed that the test item-formulation was correctly prepared. The actual concentration of iron in the formulation solution ranged from 92% to 96% and was well within the expected range of 90% to 110% of the theoretical concentration.
ANALYTIC OF REFERENCE ITEM:
1) Reference item (iron (III) citrate tribasic monohydrate):
The total iron content of the reference substance iron(III) citrate tribasic monohydrate determined after digestion by ICP-OES amounts to 21.2 % [w/w]. Measured iron, citrate and water contents of 21.2, 67.83 and 10.2 all in % [w/w], respectively, add up to 99.23 % [w/w]. Impurities were quantified in total with 0.19 % [w/w].
The iron content of 18.7% reported by the material supplier reflects only Fe(II) because of the iodometric titration employed. Considering measurement uncertainties, the reference substance iron(III) citrate tribasic monohydrate is considered adequately characterised, and the value of 21.2% total iron content should be taken forward.
Description of key information
The dissolved Fe concentrations from nano-material under simulated physiological conditions were highest in artificial lysosomal fluid (ALF, pH 4.56.96 µg/L, 29.0 µg/L and 80.5 µg/L of iron were found in the dissolved phase after 2, 24 and 168 h. Therefore, with a maximum mean released fraction of <0.1% after 168 h, the dissolution of iron hydroxide oxide yellow was highest in artificial lysosomal fluid (ALF).
An absolute bioavailability of 0.26%/0.21% (m/f) for iron hydroxide oxide yellow was calculated for iron following oral administration compared to intravenous administration. However, it should be noted that this evaluation was done on the substance-specific data without consideration of the vehicle control.
The plasma iron levels of the dosed group falls within the boundaries of the vehicle control group which reflects long established daily circadian variation of plasma iron levels. Hence, the calculated absolute bioavailability derived by the pharmacokinetic analysis can therefore be seen as conservative overestimates, thus leading to the conclusion that the bioavailability of iron from the tested oxide is similarly minimal to negligible.
Key value for chemical safety assessment
- Bioaccumulation potential:
- no bioaccumulation potential
Additional information
A category approach justification for the iron oxides - Fe2O3, Fe3O4, FeOOH, (Fe,Mn)2O3, (Fe,Mn)3O4, ZnFe2O4 - was developed.
In the updated category approach justification, the category was extended and includes additional information on nano- and/or powder material to justify that the category covers nano- and micro-sized materials.
The members of the category are insoluble, inert particles. Conclusive evidence of bioavailable iron or iron particles that were translocated to extrapulmonary organs after inhalation was not observed in repeated dose toxicity studies (see endpoint summary repeated dose toxicity; Pauluhn, 2005). Due to its structure and physico-chemical properties (insoluble in water and organic solvents) absorption and bioaccumulation is negligible if no overload effect of the lung occurs – see Category Approach Justification - Iron oxides.
As demonstrated in the category approach justification, in regard to structure, physicochemical properties, environmental fate characteristics, ecotoxicity and toxicity, the grouping of Fe2O3 (diiron trioxide), Fe3O4 (triiron tetraoxide), FeOOH (iron hydroxide oxide), (Fe,Mn)2O3 (iron manganese trioxide), (Fe,Mn)3O4 (manganese ferrite), and ZnFe2O4 (zinc ferrite) in the "Iron Oxides Category" is justified.
In the updated category approach justification , the category was extended to nano- and/or powder material. Comprehensive and sufficient data are available to conclude that nano- and micro-sized category member behave similar and no further testing is necessary.
Notably, from the results of repeated dose inhalation studies with FeOOH, Fe2O3 or Fe3O4 any size dependent increased translocation of iron outside the lung did not occur. Therefore no systemic toxicity for nano- and powder material of the iron oxides exists.
These repeated dose toxicity studies demonstrated, that the occupational limit value for nano- and powder material is identical.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.