Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin sensitisation

Currently viewing:

Administrative data

Endpoint:
skin sensitisation: in vivo (LLNA)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2020-04-01 to 2020-05-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 429 (Skin Sensitisation: Local Lymph Node Assay)
Version / remarks:
2010
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method B.42 (Skin Sensitisation: Local Lymph Node Assay)
Version / remarks:
EC No 640/2012, Part B: "Skin Sensitization: Local Lymph Node Assay"
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 870.2600 (Skin Sensitisation)
Version / remarks:
2003
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of study:
mouse local lymph node assay (LLNA)

Test material

Constituent 1
Chemical structure
Reference substance name:
1-[2-[2-methoxy-4-(morpholin-4-yl)-5-nitroanilino]pyrimidin-4-yl]-3-phenyl-1H-pyrazole-4-carbaldehyde
Cas Number:
1903010-39-8
Molecular formula:
C25H23N7O5
IUPAC Name:
1-[2-[2-methoxy-4-(morpholin-4-yl)-5-nitroanilino]pyrimidin-4-yl]-3-phenyl-1H-pyrazole-4-carbaldehyde
Test material form:
solid: particulate/powder
Details on test material:
- Physical state: solid
- Appearance: orange powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch number of test material: I19HD2158
- Expiration date of the lot/batch: 2020-09-01
- Physical Description: Orange powder
- Purity: 100.4%
- Purity test date: 2019-09-01


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature
- Stability under storage conditions: not indicated
- Stability under test conditions: not indicated
- Solubility and stability of the test substance in the solvent/dispersant/vehicle/test medium: the vehicle was chosen from the vehicles specified in the test guideline (in order of preference): Acetone/Olive oil (4:1 v/v), N,N-dimethylformamide, methylethylketone, propylene glycol, dimethylsulfoxide and 1% Pluronic©L92 in Elix water (in case an aqueous vehicle is suitable). The vehicle was selected on the basis of maximizing the solubility based on trial preparations performed at Charles River Den Bosch and on information provided by the Sponsor. Trial preparations were performed to select the suitable vehicle and to establish a suitable formulation procedure. Acetone/Olive oil (4:1 v/v), N,N-dimethylformamide, methylethylketone and dimethylsulfoxide did not provide homogenous formulations at a 50 or 20% concentration. Propylene glycol did provide a homogenous formulation at a 20% concentration and was therefore selected. These trials were not performed as part of this study and these preparations were not used for dosing. There was no information available about the stability and solubility of the test item in vehicle.


TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: the test item was dissolved in propylene glycol at a 20 % concentration (w/w)
- Preliminary purification step (if any): not indicated
- Final preparation of a solid: Test item dosing formulations (w/w) were homogenized to visually acceptable levels at appropriate concentrations to meet dose level requirements. The dosing formulations were prepared daily and dosed within 4 hours after adding the vehicle to the test item. The dosing formulations were kept at room temperature until dosing. The dosing formulations were stirred until and during dosing. No adjustment was made for specific gravity of the vehicle and no correction was made for the purity/composition of the test item, since the test method requires a logical concentration range rather than specific dose levels.

FORM AS APPLIED IN THE TEST (if different from that of starting material): liquid

OTHER SPECIFICS
- Correction factor: 1

In vivo test system

Test animals

Species:
mouse
Strain:
CBA:J
Sex:
female
Details on test animals and environmental conditions:
TEST ANIMALS
- Source: female (nulliparous and non-pregnant) mice, CBA/J strain, inbred, SPF-Quality from Janvier, Le Genest-Saint-Isle, France
- Age at study initiation: approx. 10 weeks old
- Weight at study initiation: 19.5 to 24.9 grams
- Housing: group housed in labeled polycarbonate cages (Makrolon MIII type; height 18 cm) containing sterilised wooden fibers as bedding material equipped with water bottles.
- Diet (e.g. ad libitum): ad libitum, pelleted rodent diet
- Water (e.g. ad libitum): ad libitum, municipal tap water
- Acclimation period: at least 5 days before the commencement of dosing

ENVIRONMENTAL CONDITIONS
- Temperature (°C): 18 to 24°C (actual: 22 to 23 °C)
- Humidity (%): 40 to 70% (actual 41 to 47%)
- Air changes (per hr): at least 10 air changes/hour with 100% fresh air (no air recirculation)
- Photoperiod (hrs dark / hrs light): 12/12

IN-LIFE DATES: From: 2020-04-01 To: 2020-05-11

Study design: in vivo (LLNA)

Vehicle:
propylene glycol
Concentration:
0, 2, 10 and 20% (w/w)
No. of animals per dose:
5 females per group; 4 groups
Details on study design:
RANGE FINDING TESTS:
- A pre-screen test was conducted in order to select the highest test item concentration to be used in the main study. In principle, this highest concentration should cause no systemic toxicity, may give well-defined irritation as the most pronounced response (maximum grade 2 and/or an increase in ear thickness < 25%) and/or is the highest possible concentration that can technically be applied.
- Two test item concentrations were tested; 10% and 20%. The highest concentration was the highest concentration that could be prepared homogeneously.
- The test system, procedures and techniques were identical to those used in the main study except that the animals were approximately 10-11 weeks (at initiation of treatment) and that the assessment of lymph node proliferation and necropsy were not performed. Two young adult females per concentration were selected. Each animal was treated with one concentration on three consecutive days. Animals were group housed in labeled Makrolon cages (MII type, height 14 cm). Ear thickness measurements were conducted using a digital thickness gauge (Kroeplin C110T-K) prior to dosing on Days 1 and 3, and on Day 6.
- Animals were sacrificed after the final observation.
- Pre-screen test results: at 10% and 20% test item concentrations, no signs of systemic toxicity were noted, and only very slight irritation was observed at a 20% concentration. Therefore, a 20% concentration was selected as highest concentration for the main study.

MAIN STUDY
ANIMAL ASSIGNMENT AND TREATMENT
INDUCTION days 1, 2, 3
- Three groups of five animals were treated with one test item concentration per group. The highest test item concentration was selected from the pre-screen test. One group of five animals was treated with vehicle.
- The dorsal surface of both ears was topically treated (25 μL/ear) with the test item, at approximately the same time on each day for three consecutive days. The concentrations were stirred with a magnetic stirrer immediately prior to dosing.
- The control animals were treated in the same way as the experimental animals, except that the vehicle was administered instead of the test item.

EXCISION OF THE NODES - day 6
- Each animal was injected via the tail vein with 0.25 mL of sterile phosphate buffered saline (PBS) (Merck, Darmstadt, Germany) containing 20 μCi of ³H-methyl thymidine (PerkinElmer Life and Analytical Sciences, Boston, MA, US).
- After five hours, all animals were euthanized according to laboratories Standard Operating Procedures. The draining (auricular) lymph node of each ear was excised. The relative size of the nodes (as compared to normal) was estimated by visual examination and abnormalities of the nodes and surrounding area were recorded. The nodes were pooled for each animal in PBS.

TISSUE PROCESSING FOR RADIOACTIVITY - day 6
- Following excision of the nodes, a single cell suspension of lymph node cells (LNC) was prepared in PBS by gentle separation through stainless steel gauze (maze size: 200 μm, diameter: ± 1.5 cm). LNC were washed twice with an excess of PBS by centrifugation at 200g for 10 minutes at 4ºC. To precipitate the DNA, the LNC were exposed to 5% trichloroacetic acid (TCA) (Merck, Darmstadt, Germany) and then stored in the refrigerator until the next day.

RADIOACTIVITY MEASUREMENTS - day 7
- Precipitates were recovered by centrifugation, resuspended in 1 mL TCA and transferred to 10 mL of Ultima Gold cocktail as the scintillation fluid. Radioactivity measurements were performed using a Packard scintillation counter (2910TR). Counting time was to a statistical precision of ± 0.2% or a maximum of 5 minutes whichever came first. The scintillation counter was programmed to automatically subtract background and convert Counts Per Minute (CPM) to Disintegrations Per Minute (DPM).

TREATMENT PREPARATION AND ADMINISTRATION:
- The test item preparations (w/w) were prepared within 4 hours prior to each dosing.
- No adjustment was made for specific gravity of the vehicle.
- Homogeneity was assessed by visual inspection of the solutions. Correction of the purity/composition of the test item is not applicable, since the test method requires a logical concentration range rather than specific dose levels.

- Criteria used to consider a positive response:
A Stimulation Index (SI) is calculated for each group using the individual SI values. The individual SI is the ratio of the DPM/animal compared to DPM/vehicle control group mean. If the results indicate a SI ≥ 3, the test item may be regarded as a skin sensitizer.
The results were evaluated according to the Globally Harmonized System of Classification and Labelling of Chemicals (GHS) of the United Nations (2017) (including all amendments) and the Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, including all amendments. Consideration was given to the EC3 value (the estimated test item concentration that will give a SI =3).

Classification of results: UN-GHS 2007; EC-CLP 2008 EC Hazard statement
SI < 3 No sensitizer -
SI ≥ 3 Cat 1 Skin sensitizer H317: May cause an allergic skin reaction
EC3 value ≤ 2%: sub-category 1A
EC3 value > 2%: sub-category 1B
Positive control substance(s):
hexyl cinnamic aldehyde (CAS No 101-86-0)

Results and discussion

Positive control results:
A reliability check is carried out at regular intervals to check the sensitivity of the test system and the reliability of the experimental techniques as used by Charles River Den Bosch. In this study, performed in December 2019, females of the CBA/J mouse strain (Janvier, Le Genest-Saint-Isle, France) were checked for sensitivity to Alpha- Hexylcinnamaldehyde, technical grade (HCA). The females were approximately 10 weeks old at commencement of the study. The study was based on the OECD Guideline No. 429, EC No 440/2008, Part B.42 and EPA, OPPTS 870.2600 “Skin Sensitization”. Alpha- Hexylcinnamaldehyde, technical grade (CAS
no. 101-86-0) was fabricated under lot no. MKCD3159 (Sigma- Aldrich, Steinheim, Germany).
Concentrations used for this study were 5, 10 and 25% in Acetone/Olive oil (4:1 v/v; AcOO).
The SI values calculated for the item concentrations 5, 10 and 25% were 1.3, 3.4 and 5.5 respectively. An EC3 value of 9.0% was calculated using linear interpolation. The calculated EC3 value was found to be in the acceptable range of 4.8 and 19.5%.
Based on the results, it was concluded that the Local Lymph Node Assay as performed at Charles River Den Bosch is an appropriate model for testing for contact hypersensitivity. The raw data, study plan and report from this study are kept in the Charles River Den Bosch archives. The test described above was performed in accordance with Charles River Den Bosch Standard Operating Procedures and the report was audited by the QA-unit.

In vivo (LLNA)

Resultsopen allclose all
Key result
Parameter:
SI
Value:
1
Variability:
± 0.1
Test group / Remarks:
0% (w/w) group
Key result
Parameter:
SI
Value:
1.3
Variability:
± 0.2
Test group / Remarks:
2% (w/w) group
Key result
Parameter:
SI
Value:
1.7
Variability:
± 0.2
Test group / Remarks:
10% (w/w) group
Key result
Parameter:
SI
Value:
1
Variability:
± 0.2
Test group / Remarks:
20% (w/w) group
Cellular proliferation data / Observations:
CELLULAR PROLIFERATION DATA:
mean DPM ± SEM:
0% w/w group: mean DPM ± SEM: 234 ± 35
2% w/w group: mean DPM ± SEM: 312 ± 50
10% w/w group: mean DPM ± SEM: 401 ± 49
20% w/w group: mean DPM ± SEM: 242 ± 56
DPM = Disintegrations per minute
SEM = Standard Error of the Mean

EC3 CALCULATION
Since there was no indication that the test item elicits a SI ≥3 when tested up to 20%, it was established that the EC3 value (the estimated test item concentration that will give a SI =3(if any) exceeds 20%. The response of the 20% group did not follow the expected dose-response relationship which is more often seen in these kinds of studies. The response might be less due to differences in skin penetration(less vehicle present) or viscosity.

CLINICAL OBSERVATIONS:
- Skin reactions/irritation: no irritation was observed in any of the animals.
- Systemic toxicity: no mortality occurred and no clinical signs of systemic toxicity were observed in the animals. Body weights and body weight gain of experimental animals remained in the same range as controls over the study period, except for one animal of the 20% test item group that showed marked body weight loss. Since there were no corroborative findings for this animal, it was considered that the results for these animals were not affected.
- Macroscopy of the auricular lymph nodes and surrounding area: all auricular lymph nodes of the animals of the experimental and control groups were considered normal in size except for one animal in the 10% test item group which had one node slightly enlarged. No macroscopic abnormalities of the surrounding area were noted for any of the animals.
- Radioactivity measurements and SI values: mean DPM/animal values for the experimental groups treated with test item concentrations 2, 10 and 20% were 312, 401and 242 DPM, respectively. The mean DPM/animal value for the vehicle control group was 234 DPM. The SI values calculated for the test item concentrations 2, 10 and 20% were 1.3, 1.7 and 1.0, respectively.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Since there was no indication that the test item elicits a SI ≥ 3 when tested up to 50%, JNJ-73848255-AAA (T003902) was considered not to be a skin sensitizer. It was established that the EC3 value (the estimated test item concentration that will give a SI =3) (if any) exceeds 50%.
Based on these results, JNJ-73848255-AAA (T003902) is not regarded as a skin sensitizer according to the recommendations made in the test guidelines. The test item does not have to be classified and has no obligatory labelling requirement for sensitization by skin contact according to the Globally Harmonized System of Classification and Labelling of Chemicals (GHS) of the United Nations (2017) (including all amendments) and the Regulation (EC) No 1272/2008 on classification, labelling and packaging of items and mixtures (including all amendments).