Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: EC Regulation No.440/2008- Annex A.10 Flammability (Solids)
Deviations:
no
Principles of method if other than guideline:
The test is carried out according to “Annex A.10” in EC Regulation No.440/2008. The
sample is formed into an unbroken strip or powder train about 250 mm long and a preliminary
screening test performed to determine if, on ignition by a flame, propagation by burning with
flame or smouldering occurs. If propagation over 200 mm of the train occurs within a specified
time then a full test programme to determine the burning rate is carried out.
GLP compliance:
no
Key result
Test procedure:
burning time over 250 mm for metal powders or metal alloys
Burning time:
< 2 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
GHS criteria not met
Conclusions:
The sample is not a highly flammable solid.
Executive summary:

The test showed that the sample could be ignited
within 2 min but could not burn 200 mm along the
power train within the 4 min test period.
Conclusion: the sample is not a highly flammable solid.

Description of key information

the sample is not a highly flammable solid.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification