Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental dates: 03 April to 31 July 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study was conducted according to an internationally recognised method, and under GLP. No deviation affected the quality of the study. The substance is adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
Commission Regulation (EC) No 440/2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
issued 01/08/2019
Type of method:
differential scanning calorimetry
Specific details on test material used for the study:
Storage Conditions: Refrigerated (2 to 8°C), dark, in an amber glass bottle.
Key result
Boiling pt.:
ca. 300 °C
Atm. press.:
ca. 1 atm
Decomposition:
yes
Decomp. temp.:
>= 160 °C

An exotherm from approximately 160°C indicated decomposition of the test item, while a very broad endotherm centred at approximately 300°C was consistent with boiling of the degraded sample. A black residue was present in the crucible after testing.

Executive summary:

The boiling point of the test substance was determined under GLP according to OECD103/EU A2 guidelines.

A first test with the Siwoloboff capillary method suggested degradation upon heating, which was confirmed using the Differential Scanning Calorimetry (DSC) method.

The substance decomposes from ca 160°C, before boiling..

Endpoint:
boiling point
Type of information:
(Q)SAR
Adequacy of study:
supporting study
Study period:
July 20, 2020
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a (Q)SAR model, with limited documentation / justification, but validity of model and reliability of prediction considered adequate based on a generally acknowledged source
Justification for type of information:
1. SOFTWARE
EPI Suite (US EPA) v4.1

2. MODEL (incl. version number)
MPBPWIN v1.43 (September 2010)

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
O=C1CCC(CCCCC)CO1

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
generally acknowledged source

5. APPLICABILITY DOMAIN
The model is considered suitable as all fragments are described and for MW < 1000 g/mol.

6. ADEQUACY OF THE RESULT
The estimation is provided to be used as input for the prediction of Vapour Pressure, as the bp could not be experimentally determined.
Principles of method if other than guideline:
QSAR calculation
GLP compliance:
no
Boiling pt.:
283.16 °C
Atm. press.:
1 atm

adapted Stein and Brown method

Executive summary:

The vapour pressure of the substance was modelled with the MBBPVP Vapour Pressure Estimation tool, which is part of the US EPA Episuite modelling tool box.

The substance was characterised with its SMILES code.

The predicted normal Boiling Point is 283°C.

Description of key information

The substance decomposes from ca 160°C, before boiling..

Key value for chemical safety assessment

Additional information

A fully reliable experimental study, conducted according to a recognized OECD/EU method and under GLP, is available.

It is considered as a key study, however, as the substance was found to decompose, no transition value can be retained as key data.