Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 July 2016 to 09 September 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
>= 6.51 - ca. 10
Temp.:
40 °C
pH:
6.8
Remarks on result:
other: range reported is 6.51 to > 10
Details on results:
PRELIMINARY ESTIMATE
- The Log10 Pow of the test item based on representative structures provided by the sponsor was calculated to be in the range 6.74 to 9.86.

DEFINITIVE TEST
- Typical chromatography is presented in Appendix 1 (attached).
- Retention times of the dead time and the retention times, capacity factors (k’) and Log10 Pow values for the reference standards are shown in Table 10 (attached).
- The calibration curve from which the sample results were taken is shown in Figure 3 (attached).
- The retention times, capacity factors and Log10 Pow values determined from the sample are shown in Table 11 (attached).
- Overall Log10 Pow range: 6.51 to > 10
Conclusions:
The partition coefficient of the test item was determined to be in the range 3.24 x 10E06 to > 1.0 x 10E10 with the associated Log10 Pow range being 6.51 to > 10. By percentage area normalisation, 97.6 % of the test item had a partition coefficient of greater than 1.0 x 10E10 (Log Pow > 10).
Executive summary:

GUIDELINE

The determination was carried out by the HPLC method using a procedure designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.

 

RESULTS

The partition coefficient of the test item was determined to be in the range 3.24 x 10E06 to > 1.0 x 10E10 with the associated Log10 Pow range being 6.51 to > 10. By percentage area normalisation, 97.6 % of the test item had a partition coefficient of greater than 1.0 x 10E10 (Log Pow > 10).

Description of key information

The partition coefficient of the test item was determined to be in the range 3.24 x 10E06 to > 1.0 x 10E10 with the associated Log10 Pow range being 6.51 to > 10. By percentage area normalisation, 97.6 % of the test item had a partition coefficient of greater than 1.0 x 10E10 (Log Pow > 10).

Key value for chemical safety assessment

Log Kow (Log Pow):
10
at the temperature of:
40 °C

Additional information

GUIDELINE

The determination was carried out by the HPLC method using a procedure designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.

 

RESULTS

The partition coefficient of the test item was determined to be in the range 3.24 x 10E06 to > 1.0 x 10E10 with the associated Log10 Pow range being 6.51 to > 10. By percentage area normalisation, 97.6 % of the test item had a partition coefficient of greater than 1.0 x 10E10 (Log Pow > 10).